5.
Install the dipstick.
6.
Reset the AUTO/OFF/MANUAL switch to its original position.
7.
If the generator was running during a utility outage, first turn
the generator's main circuit breaker back to the ON position.
Second, turn ON needed loads in the residence.
Figure 4.3 — Oil Dipstick and Fill,
14, 17 & 20kW
Oil Dipstick
4.3
CHANGING THE ENGINE OIL
Hot oil may cause burns. Allow engine to cool
before draining oil. Avoid prolonged or repeated
skin exposure with used oil. Thoroughly wash
exposed areas with soap.
4.3.1
OIL CHANGE INTERVALS
See the "Service Schedule" section.
4.3.2
ENGINE OIL RECOMMENDATIONS
All oil should meet minimum American Petroleum Institute (API)
Service Class SJ, SL or better. Use no special additives. Select
the oil's viscosity grade according to the expected operating tem-
perature.
•
SAE 30
Above 32° F
•
10W-30
Between 40° F and -10° F
•
Synthetic 5W-30
10° F and below
1 0W -3 0
1 0W - 30
Synthetic 5W-30
Synt he ti c 5W -3 0
Oil Fill
SAE 3 0
SAE 30
Section 4 — Maintenance
Air-cooled Generators
Any attempt to crank or start the engine before
it has been properly serviced with the recom-
mended oil may result in an engine failure.
4.3.3
OIL & OIL FILTER CHANGE PROCEDURE
To change the oil, proceed as follows:
1.
Start the engine by moving the AUTO/OFF/MANUAL switch to
MANUAL and run until it is thoroughly warmed up. Then shut
OFF the engine by moving the switch to the OFF position.
2.
Immediately after the engine shuts OFF, pull the oil drain hose
(Figure 4.4) free of its retaining clip. Remove the cap from the
hose and drain the oil into a suitable container.
3.
After the oil has drained, replace the cap onto the end of the
oil drain hose. Retain the hose in the clip.
Change the engine oil filter as follows:
1.
With the oil drained, remove the old oil filter by turning it
counterclockwise.
2.
Apply a light coating of clean engine oil to the gasket of the
new filter. See the Specifications section for recommended
filter.
3.
Screw the new filter on by hand until its gasket lightly contacts
the oil filter adapter. Then, tighten the filter an additional 3/4 to
one turn (Figure 4.4).
4.
Refill with the proper recommended oil (see the Engine Oil
Recommendations section). See the Specifications section
for oil capacities.
Figure 4.4 – Oil Drain Hose and Filter
Low Oil Switch
Oil Filter
Oil
Drain
Hose
5.
Start the engine, run for one (1) minute, and check for leaks.
6.
Shutdown and recheck oil level, add as needed. DO NOT
OVER FILL.
7.
Reset the AUTO/OFF/MANUAL switch to the AUTO position.
8.
Dispose of used oil at a proper collection center.
High Temp Switch
23