Technical Data - Mennekes AMEDIO Proffesional+PnC 22 T2S Manual De Instrucciones Y De Instalación

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 87
4

Technical data

Charging power Mode 3 [kW] *
Rated voltage U
[V]
N
Rated frequency f
[Hz]
N
Rated current I
[A]
nA
Maximum backup fuse [A]
Protection degree
Protection class
Dimensions H x W x D [mm]
Weight [kg]
Rated insulation voltage U
Rated impulse withstand voltage U
Rated current of charging point circuit I
Rated conditional short-circuit current of charging
points circuit I
[kA]
cc
Rated diversity factor (RDF)
Pollution degree
Overvoltage category
Types of system earthing
Installation
Stationary / Mobile
Usage
External design
EMC classification
Mechanical impact protection
Terminals
Terminals for supply
Clamping range [mm²]
line
Tightening torque [Nm]
Supply line **
Surge protection
Ethernet
Lightning and surge
Supply line **
protection
Standard
* The device can be operated in single-phase or three-phase. MID approved only for the three-phase mains connection.
** optional
[V]
i
[kV]
imp
[A]
nC
Professional+ (PnC) 22 (T2S),
Professional+ 22 customized-1
2 × up to 22
400 AC ±10 %
1362 × 352 × 252
32, 1 ph / 3 ph
TN / TT (IT only under certain conditions
cf. "5.4.1 Power supply")
Stationary
Floor-mounted
5 × 2 × 35 mm²
Rigid / Flexible 1.5 - 50
Flexible with ferrules fitted 1.5 - 35
Type 2, pluggable, max. peak surge current 40 kA (8 / 20 µs)
Secondary protection, total peak surge current 5 kA
(8 / 20 µs)
Typ 1 + 2, pluggable, lightning surge current 12,5 kA
(10 / 350 µs), max. peak surge current 50 kA (8 / 20 µs)
EN 61851, DIN IEC / TS 61439-7
50
63
100
IP 54
I
45 - 50
500
4
10
1
3
III
Outdoors
AEVCS
A+B
IK10
3.2 - 3.7
EN
9

Publicidad

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

Amedio proffesional +22 customized-1

Tabla de contenido