Block 8: Charging settings
Parameter
Free charging
Free charging mode
Rfid Tag for Free Charging with
OCPP Full, fixed rfid modes
If in doubt allow charging
Block 9: Charging current
Parameter
Operator Current Limit (A)
Block 10: Dynamic load management (DLM)
A detailed description of load management with application examples can be found on our website in the
download section of the selected product.
Parameter
Description
Dynamic Load
Used to set the charge point function for load
Management
management in a DLM network
DLM Network Id
Setting that specifies which DLM network ID the
charge point is assigned to
DLM Master IP and
IP address of the DLM master that controls the
port
charging point. The port can also be specified
Disable Discovery
Setting that specifies whether Discovery
Broadcasting
Broadcasting is disabled on the DLM-Master
DLM Algorithm
Duration required to determine the algorithm
Sample Rate
Allow EV Wakeup
Setting that species whether to continue to provi-
de charging current after charging the vehicle
Description
Charging without authorization. Charging
process begins as soon as a vehicle is
plugged in
Setting the OCPP behavior
RFID UID for the mode "Full fixed Rfid"
Emergency charging if no Backend-System
is connected
Description
Maximum charging cur-
rent
Necessary for ... Remark
Authorization
Necessary for ...
Remark
Charging system
This setting has to be made sepa-
rately in the slave web interface
Necessary
for ...
Charging
system
Only when "Free
charging" = "On"
This setting has to
be made separate-
ly in the slave web
interface
Remark
This setting has to be made
separately in the slave web
interface
This setting has to be made
separately in the slave web
interface
Format: Any number bet-
ween 0 and 255
This setting has to be made
separately in the slave web
interface
For the assignment of static
IP addresses, this parameter
must be set to "On"
EN
29