Installation

The tasks described in this section may only be
carried out by a qualified electrician.
5.1

Choice of location

The device is solely intended for fixed floor mounting. A
suitable location meets the following requirements:
„ Technical data and mains data are the same.
Î "4 Technical data"
„ Permissible ambient conditions are observed.
„ The minimum distances are respected.
„ Connection to a Backend-System: The mobile network
for connection to the Backend-System must be fully
available at the location.
„ "Networked" operating mode: Networked devices are
in sufficient proximity to each other (the ethernet cable
may not exceed 100 m in length).
„ The device and the charging station are in sufficient
proximity to each other, depending on the charging
cable used.
5.1.1

Permissible ambient conditions

T
DANGER
Danger of injury and fire
If the device is operated in potentially explosive atmos-
pheres (explosive area), explosive substances may ignite
due to sparking of components of the device.
f Do not use the device in potentially explosive atmos-
pheres (e.g. gas filling stations).
T
ATTENTION
Device damage due to unsuitable ambient conditions
Unsuitable ambient conditions can result in device dam-
age.
f Protect the device from a direct water jet.
f Do not install the device in flood-prone areas.
f Ensure adequate ventilation of the device. Do not
install in niches.
f Keep device away from heat sources.
f Avoid large temperature fluctuations.
MENNEKES recommends protecting the device
with curbs or bollards provided by the customer.
10
MENNEKES recommends using pedestal filler for
protection against humidity and insects.
Permissible ambient conditions
Ambient temperature
Average temperature
over 24 hours
Altitude
Relative humidity

5.1.2 Minimum distances

T
ATTENTION
Damage to the device due to insufficient ventilation
Insufficient ventilation may lead to overheating and thus to
damage to the device.
f Observe the specified minimum distances to other
objects (e.g. walls).
8 0
0
1 2 5 0
Fig. 5: Minimum distances [mm] (example)
-25 °C ... +40 °C
< 35 °C
Max. 2,000 m above sea
level
max. 95 % (non-condensing)
8 0
0

Publicidad