Meter configuration (Second)
IP address of second meter
Port number of Second Meter
Pulses per kWh (Second S0
meter)
Block 12: Other
Parameter
15118 Configuration
Enable TLS support for
15118
Extra logging
Power source voltage
Phases connected to
the ChargePoint
Phase rotation of the
ChargePoint
Tilt detection
Randomise charging
after power loss
Language of Display
32
External energy meter selection for
additional consumers
IP address of the external energy
meter
Port number of the external energy
meter
Description
Enables communication in accordance with ISO 15118
Activates TLS communication between the vehicle and the
charging point when TLS communication is requested from
the vehicle
Used to activate the recording of the input and output
streams of ISO 15118 communication. The log is stored in
the hlc_log.csv file
Rated voltage between phase conductor and neutral con-
ductor
Number of phases connected on the device
Direction of rotation of the phases L1, L2 and L3
Setting of tilt detection
Random delay after power failure to avoid peak currents
Charging sys-
tem
Not relevant for the device
Not relevant for the device
Only if "External Meter
Support" = "On"
Preset: "502"
Necessary
Remark
for ...
For Professional+
ISO 15118
PnC 22 (T2S)
versions only
This setting
has to be made
separately in the
slave web inter-
face
„ This setting
has to be
made sepa-
rately in the
Charging
slave web
system
interface
„ Only relevant
for three-pha-
se operation
This setting
has to be made
separately in the
slave web inter-
face

Publicidad

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

Amedio proffesional +22 customized-1

Tabla de contenido