CONNECTING PERIPHERALS

Description of the various peripherals

Key
Description
1
Orange light
2
Remote lighting
3
Code keypad
4
Keyswitch
5
Aerial
6
Battery

Electrical connections for the various peripherals

Cut the electric power supply to the motor before performing any work on peripherals. If the display remains off after working on the system, check
the wiring (for possible short circuits or polarity reversals).
General electrical diagram (Fig. 21)
Photoelectric cells (Fig. 22)
Two types of connections can be made:
A: Standard (without self test): program the setting "P2" = 2.
B: With self test: program the setting "P2" = 1.
This means that an automatic test is conducted to check photoelectric cell operation every time the door operates.
If the test fails, no door movement is possible.
Reflex photoelectric cell (Fig. 23)
With self test: program the setting "P2" = 1.
This means that an automatic test is conducted to check photoelectric cell operation every time the door moves.
If the test fails, no door movement is possible.
Sensor bar (Fig. 24)
With self test: program the setting "P2" = 1.
This is used to perform an automatic test of sensor bar operation every time the door moves.
If the test result is negative, no door movement is possible.
Make sure you have correctly configured parameter "P2" taking into account the photoelectric cells or the sensor bar.
Orange light (Fig. 25)
Program the setting "P1" depending on the required operating mode:
Without warning before door movement:
With a 2 s warning before door movement:
Code keypad (Fig. 26)
Pedestrian door safety kit (Fig. 27)
When the pedestrian door contact is fitted, it must be connected in place of the jumper normally fitted between terminals 5 and 6.
If the pedestrian door contact is removed, the jumper between terminals 5 and 6.
Battery (Fig. 28)
Aerial (Fig. 29)
Remote lighting (Fig. 30)
Class 2 (double insulation) light units that are connected do not require an earth connection.
Various types of lighting can be connected without exceeding a total power consumption of 500 W.
Siren
For more information on connecting the siren, consult the installation manual.
Programme the parameter "Pb" to activate the siren:
Siren inactive "Pb" = 0.
Siren active: "Pb" = 1 or "Pb" = 2.
6
Fig.
21
Key
7
8
9
10
11
"P1" = 0.
"P1" = 1.
Description
Pedestrian door safety kit
Photoelectric cells
Reflex type cells
Sensor bar
Siren
Fig.
21 to 30