Function Chart; Instrument Repair - Vega VEGASWING S 52 Instrucción De Servicio

Ocultar thumbs Ver también para VEGASWING S 52:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

à
Hold the test magnet (accessory) to the
magnet symbol on the instrument housing
Fig. 18: Function test
The test magnet changes the current switching
condition of the instrument. You can check the
change on the signal lamp. Please note that the
connected instruments are activated during the
test.
Caution:
It is absolutely necessary that you remove
the test magnet after the test from the
instrument housing.

5.3 Function chart

The following chart provides an overview of the
switching conditions depending on the adjusted
mode and level.
Level
Mode max.
Mode max.
VEGASWING S 52
Switching
Control
status
lamp
transistor con-
Green
ducts
or
Switch con-
ducts
transistor
red
blocks
or
Switch blocks
Level
Mode min.
Mode min.
Failure
any
6 Maintain
6.1 Maintenance
When used as directed in normal condition,
VEGASWING S 52 is maintenance-free.
6.2 24 hour service hotline
However, should this measures not be successful,
call the VEGA service hotline in urgent cases under
the phone no. +49 1805 858550.
The hotline is available to you 7 days a week
round-the-clock. Since we offer this service world-
wide, the support is only available in the English
language. The service is free of charge, only the
standard telephone costs will be charged.

6.3 Instrument repair

If a repair is necessary, please proceed as follows:
You can download a return form (23 KB) in the
Internet from our homepage www.vega.com under:
"Downloads - Forms and Certificates - Repair
form".
By doing this you help us carry out the repair
quickly and without having to call for needed
information.
Print and fill out one form per instrument
l
Clean the instrument and pack it damage-proof
l
Attach the filled in form and if necessary, a
l
safety data sheet to the instrument
Maintain
Switching
Control
status
lamp
transistor con-
Green
ducts
or
Switch con-
ducts
transistor
red
blocks
or
Switch blocks
transistor
flashes red
blocks
or
Switch blocks
15