5 Analog Input Connect

5.1 Structure and function

The Analog Input Connect allows analogue voltages to be read via 2 input channels. A voltage range of
0 V...10 V or ±10 V can be set in iEasyLab under the "Settings" menu for the Connect. The electrical
connection is established via 4 mm safety sockets.
Assignment
Socket 0
Channel AIN1: Signal
Note
When connecting the analogue signals make sure that the earth wiring is correct.

5.2 Commissioning the Connect

Proceed as follows:
1. Insert the Connect into the base.
2. The Connect is detected automatically by the base.
3. If the iEasyLab software has been started, the Connect will be detected and shown on the display.
4. Select the appropriate input voltage range.
© Festo Didactic 8034153
Socket 1
Channel AIN1: GND
The port assignment of the Connect that
has been inserted into the base will be
displayed on the iPad after starting the
iEasyLab software.