Analog Output Connect; Structure And Function; Commissioning The Connect; Technical Data - Festo Tec2Screen Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

6 Analog Output Connect

6.1 Structure and function

The Analog Output Connect allows analogue voltages to be output via 2 output channels. A voltage range of
0 V...10 V or ±10 V can be set in iEasyLab under the "Settings" menu for the Connect. The electrical
connection is established via 4 mm safety sockets.
Assignment
Socket 0
Channel AOUT1: Signal

6.2 Commissioning the Connect

Proceed as follows:
1. Insert the Connect into the base.
2. The Connect is detected automatically by the base.
3. If the iEasyLab software has been started, the Connect will be detected and shown on the display.

6.3 Technical data

Electrical/mechanical specifications
Output voltage
Output current
Connection
Resolution
Size
Weight
Subject to change
© Festo Didactic 8034153
Socket 1
Channel AOUT1: GND
The port assignment of the Connect that
has been inserted into the base will be
displayed on the iPad after starting the
iEasyLab software.
Socket 2
Channel AOUT2: Signal
±10 V
30 mA max.
4 mm safety sockets
12 bit
71 mm x 40 mm x 30 mm
42 g
Socket 3
Channel AOUT2: GND