Mode Of Operation - Lincoln 236-13870-2 Instructions De Service

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Owner Manual
Operating Instructions

Mode of Operation

Fig. 3: Printed circuit board installed in housing
Fig. 4: Printed circuit board 236-13870-2
Fig. 5: Time sequence diagram
tB - Operating hours
tP - Individual pause times
Page 4
LINCOLN GmbH • Postfach 1263 • D-69183 Walldorf • Tel +49 (6227) 33-0 • Fax +49 (6227) 33-259
00002616
20002441a
1059a95
T - Operating cycle
T1 - Stored pause times
T2 - Lubricating times
The printed circuit board is integrated in the pump housing
• The printed circuit board automatically controls the
sequence of the pause and lubricating times of the
central lubrication pump 203 as a function of the vehicle
or machine operating hours tB (Fig. 5).
• The sequence of the pause and lubricating times is
activated when the machine contact or driving switch is
switched on.
• A operating cycle consists of one pause time and one lub-
ricating time. Once the pause time has elapsed, the lubri-
cating time starts. This operating cycle is repeated perma-
nently after the vehicle or the machine has been put into
operation. Refer to Fig. 5.
• During the lubricating time the pump element dispenses
the lubricant to the lubrication points via progressive mete-
ring devices.
2.6A-28003-B06

Publicidad

Tabla de contenido
loading

Tabla de contenido