Lincoln 236-13870-2 Instructions De Service página 23

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Owner Manual
Operating Instructions
Fig. 13: Rotary switch Pause time
Switch
1
position
Minutes
4
Hours
1
Fig. 14: Preselection of the time ranges
Pause time
Monitoring time
Monitored circuits
LINCOLN GmbH • Postfach 1263 • D-69183 Walldorf • Tel +49 (6227) 33-0 • Fax +49 (6227) 33-259
20002454a
2
3
4
5
8
12
16
20
2
3
4
5
20002448a
To set the pause time
The pause time can be set to 15 different settings by means of
the blue rotary switch.
Time ranges: minutes or hours
6
7
8
9
24
28
32
36
6
7
8
9
Note: The 0 position corresponds to the shortest time.
Factory Setting
• The time ranges (hours or minutes) can be modified by
replugging the jumper of the printed circuit board (Fig. 14).
Rotary switch on .............................................................. 6 hours
or ................................................................................ 24 minutes
Jumper on : .................................................................. 5 minutes
or ................................................................................ 30 minutes
Jumper on : ...................................................................... 1 circuit
or .................................................................................... 2 circuits
2.6A-28003-B06
A
B
C
D
40
44
48
52
10
11
12
13
E
F
56
60
14
15
Page 9

Publicidad

Tabla de contenido
loading