Fault Acknowledgement
Fig. 11: To acknowledge a fault

To Remedy to a Fault

* In the case of a fault, check whether the central lubrication
pump and the connected system are malfunctioning.
* Correct the cause of the fault.
* Switch the pump on again by triggering an additional lubrica-
tion cycle. For this, press the pushbutton >2 seconds.
• When the fault is eliminated, the signal lamp will extinguish at
the end of the lubrication cycle.

Time Setting

Fig. 12: The cover to the printed circuit board has been removed
Page 8
LINCOLN GmbH • Postfach 1263 • D-69183 Walldorf • Tel +49 (6227) 33-0 • Fax +49 (6227) 33-259
• When the pushbutton is pressed briefly (< 1 second) the fault
is acknowledged, i.e. the lamp stops flashing and is perma-
nently lit.
Note: Any acknowledged fault remains stored even after the dri-
ving switch or machine contact has been switched off. Upon
switching on again, the signal lamp flashes again in accordance
with the fault.
20002458
Important: If there has been any fault, the pump will not start
automatically after the correction of that fault. It must be swit-
ched on, i.e. an additional lubrication cycle must be triggered.
See item " To trigger an additional lubrication cycle".
Note: It is also possible to acknowledge or reset a fault or trigger
an additional lubrication cycle by means of the pushbutton on
the printed circuit board (Fig. 15). For this, press it < 1 second
and > 2 seconds. Condition: The machine contact or driving
switch must be switched on.
* To set the pause time, remove the cover on the pump hou-
sing.
Note: To reset a jumper, remove the printed circuit board.
Important: After having set the pause time, screw the cover on
the pump housing again.
00002617