Monitoring Time; Functional Check - Lincoln 236-13870-2 Instructions De Service

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Owner Manual
Operating Instructions
Fig. 8: Monitoring ranges
1 - Jumper for monitoring time
2 - Jumper for
or
Fig. 9: LED display for the monitoring time or indication of faults
Page 6
LINCOLN GmbH • Postfach 1263 • D-69183 Walldorf • Tel +49 (6227) 33-0 • Fax +49 (6227) 33-259
5 min
5 minutes
30 min
30 minutes
1 circuit
1 O
2 circuits
2 O
10012434a

Monitoring time

• A fixed monitoring time of max. 5 or 30 minutes (depending
on the jumper position) runs in parallel to the lubricating
time.
Note: Normally, the monitoring time ends at the same time as
the lubricating time.
• If there is no switching off signal from the piston detector
to the printed circuit board within 5 or 30 minutes, a fault
signal will occur.
The signal lamp flashes with the corresponding flashing
frequency. See "Fault indication".
• If the lubricating time exceeds 5 minutes, the monitoring
time can be changed from 5 to 30 minutes by replugging
the jumper.
20002459
• If there are two monitored lubrication cycles, the jumper
must be plugged to (2 "O").

Functional check

• Each time the machine contact (external contact) or the dri-
ving on switch is switched on, a functional check of the drive
motor and signal lamp takes place automatically.
• During the functional check the motor is switched on for 0.1
second (the stirring paddle slightly rotates) and the signal
lamp lights up for 2 seconds.
• If there is a fault, the signal lamp flashes. See "Fault indica-
tion".
Note: LED Fig. 9 indicates the same operating states as the
signal lamp.