Rated voltage ........................................................... 12/24V DC
Operating voltage
12V/ 24V ................................................................ 9V to 30V
Residual rippple in relation
with the operating voltage ................. ± 5% acc. to DIN 41755
Motor output ........................... transistor 7A/short-circuit proof
Reverse voltage protection:
The operating voltage inputs are protected against
polarity reversal
Temperature range: ..................................... -25°C to 70°C
Output fault/readiness for operation
.................................... transistor 3A/short-circuit proof
Class of protection
Printed circuit board installed in housing ...................IP 6K 9K
In order to protect the printed circuit board against condensa-
tion, it has been covered with a protection varnish.
All the printed circuit boards meet the EMC (Electromagnetic
compatibility) guidelines for road vehicles acc. to DIN 40839
T1, 3 and 4.
LINCOLN GmbH • Postfach 1263 • D-69183 Walldorf • Tel +49 (6227) 33-0 • Fax +49 (6227) 33-259

Technical Data

The printed circuit boards model M comply with the EMC gui-
deline 89 / 336 / EWG
Emitted interference acc. to ................. EN 55011 / 03.91 and
........................................................ EN 50081-1 / 01.92
Noise immunity acc. to .............................. EN 50082-2 / 1994
Time Setting
Pause time, acc.to jumper position:
................................................. 4, 8, 12,...to 60 minutes
or ..................................................... 1, 2, 3...to 15 hours
The lubricating time is switched off via the piston detector.
Factory setting
Pause time .............................................................. 6 hours
or ...................................................................... 24 minutes
Monitoring time ................................................... 5 minutes
or ...................................................................... 30 minutes
Monitored lubrication circuit ................................... 1 circuit
or .......................................................................... 2 circuits