Owner Manual
Operating Instructions
Fig. 6: Sequence of a lubricaton cycle
A - Monitoring of the motor and signel lamp
B - Sequence of the lubricating time
C - Sequence of the monitoring time
I - Lubricating time
P - Pause time
Fig. 7: Piston detector
LINCOLN GmbH • Postfach 1263 • D-69183 Walldorf • Tel +49 (6227) 33-0 • Fax +49 (6227) 33-259

Pause time

• The pause time
- determines the frequency of the operating cycles within a
working cycle;
- is started and stopped via the machine contact or driving
switch;
- is adjustable.
• When the machine contact or the driving switch is switched
off, the pause time which have already elapsed as well as
the momentary operating conditions (fault) are stored and
added up by an electronic memory (EEPROM) until the time
which has been set on the blue rotary switch is reached.
• After the machine contact or driving switch is switched on
again, the printed circuit board operates from the point whe-
1158b95
re it had been interrupted.
• If the setting is modified within the pause time, the printed
circuit board takes over the new value only at the end of the

lubricating time.

• The pause time setting may be different for each applicati-
on. It must be adjusted in accordance with the respective
operating cycles. Also refer to "To set the pause time".
Lubricating time
• A piston detector (initiator) which has been installed on a
metering device instead of a piston closure plug monitors
and brings the pump lubricating time to a close after all the
pistons of this metering device have dispensed their lubri-
cant quantity.
• The lubricating time depends on the system's lubricant
requirement and the location of the piston detector (instal-
led either on the main metering device or on the secondary
metering device).
Note: If two lubrication cycles are monitored, the lubrica-
ting time ends after the two piston detectors have transmit-
ted their signal to the printed circuit board.
• During the lubricating time, the signal lamp is permanent-
4 3 0 9 a 0 1
ly lit.
M 00 - M 07
• If the lubricating time is interrupted within the monitoring
time (switching off of the machine contact or driving
switch), it will start again from the beginning after it is
switched again.
M 08 - M 16
The lubricating time always completely elapses even if the
machine contact or the driving switch is switched off.
2.6A-28003-B06
Page 5