Technical Data - Starmix GS Serie Instrucciones Para El Manejo

Ocultar thumbs Ver también para GS Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 15
4.
Finishing vacuuming and cleaning
4.1.
Pull the power plug of the vacuum
4.2. Pull the power plug on the pump of the vacuum
4.3.
Take the pump from the vacuum cleaner and empty
the residual water from the tank and any residual
water from the vacuum or runoff hose.
4.4.
Cleaning the pump.
Pull the power plug
before cleaning.
Insert a suitable tool (such as
a screwdriver) into one of
the openings of the vacuum
basket and pry it from the pumping housing.
Clean with a
powerful water jet
vacuum basket
impeller and
pumping housing
To clean the magnetic float,
disassemble the slit plastic
disc from the skid pipe of
the magnetic float.
Remove the magnetic float
from the skid pipe.
The cast ring magnet of the magnetic floats is
fragile. This is the reason why you should be
careful about installing, removing and cleaning it.
Clean the
plastic disc
magnetic float
skid pipe
float housing
Insert the magnetic float onto the skid pipe with the
ring magnet disc.
Insert the slit plastic disc onto the skid pipe again.
Make sure that the plastic disc has caught onto the
groove of the skid pipe on the entire circumference.
Press the vacuum basket onto the pumping housing
again until it catches.
No other cleaning is
4.5.
Clean the tank and all
check the suction openings for permeability.
4.6.
Wash out the foam filter when vacuuming without a
filter bag (refer to accessories).
10
cleaner.
cleaner.
required on the pump.
nozzles and pipes, etc. and
5.
FSN 80 Filter Sack
order number 42 40 71
reusable plastic filter with a 80
mesh .
easy to
clean.
5.1 Mounting the FSN 80 Filter Sack
5.1.1 Insert the filter sack
intake fittings.
5.1.2
Screw mounting Y onto the intake fittings with the
bayonet seal.
It only has to be mounted in connection
with the filter sack
5.1.3 Mounting
order number 57 33 04

6. Technical Data

6.1 Immersion Pump/
Dirty-Water Pump
Pump model
Housing dimensions
Thread size of pump connections G 1
Length of power cable
Weight
Operating voltage
Frequency
Power consumption
Output P1
Output P2
Pump capacity
Maximum temperature
of pumping medium
Maximum grain size
Maximum pump head
Automatic switch-on
Automatic switch-off
Safety contact
These data only refer to the pump
(not in connection with the vacuum cleaner)
μm
X onto the tank and thread in
safety contact
ON
OFF
650 watts
H = 282 mm/Ø = 175 mm
1
/
" i
4
1,2 m
5,4 kg
230 V~
50 Hz
3,1 A
650 watts
0.38 kW
300 l/min.
max. +45° C
10 mm
9 m
145 mm
70 mm
260 mm

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Hs serieGs pa-1455Hs pa-1455

Tabla de contenido