SICK FLOWSIC500 Instrucciones De Servicio página 137

Caudalímetro ultrasónico de gas con conversión opcional del volumen
Ocultar thumbs Ver también para FLOWSIC500:
Tabla de contenido

Publicidad

Anexo
Fig. 63
Código de tipo FLOWSIC500 (explicación)
1
Device type
FL5
2
Nominal size adapter
X
1
2
3
D
3
Flange-flange dimension adapter
X
A
B
E
G
L
4
Pressure rating / flange standard
01
02
5
Mating surface
X
A
B
C
D
6
Connection p-sensor
X
1
2
3
4
7
Connection T-sensor
X
A
E
8
Material adapter/gas meter
1
9
Material certification adapter/gas meter
A
10
Surface adapter/gas meter
1
11
Reserve
X
12
Nominal size gas meter
1
2
3
C
13
Flow direction
A
B
14
Transducer
1
15
Maximum flow rate
A
B
C
D
E
F
G
16
Measuring span
1
2
3
4
9
FLOWSIC500 · Instrucciones de servicio · 8015394/13GE/V 3-3/2019-10 · © SICK Engineering GmbH
FLOWSIC500
Replacement meter only
DN 50 / 2"
DN 80 / 3"
DN100 / 4"
DN150 / 6", adapter 4"
Replacement meter only
50 mm
171 mm
241 mm
300 mm
450 mm
PN16 / EN1092-1
Class 150 / ASME B16.5
Replacement meter only
Flat face, smooth finish
Raised face, smooth finish
Form A / DIN EN 1092-1
Form B1 / DIN EN 1092-1
Replacement meter only
Plug NPT 1/4"
Plug G1/4"
Compression fitting 1/4"
Compression fitting D6
Replacement meter only
without
2x G 1/2" plug
Aluminum / aluminum
3.1 / 3.1
Shot-peened / SICK standard
-
DN50 / 2"
DN80 / 3"
DN100 / 4"
DN150 / 6"
Left - right
Right - left
Type 1: 300 kHz
Qmax 65 m³/h
Qmax 100 m³/h
Qmax 160 m³/h
Qmax 250 m³/h
Qmax 400 m³/h
Qmax 650 m³/h
Qmax 1000 m³/h
1:50
1:100
1:160
1:200
1:250
17
Sensoric for volume correction
A
-
B
T-Sensor external
C
T-Sensor internal
D
p/T-Sensoren external
E
p/T-Sensoren internal
18
Gas temperature/ambient temperature
1
-25°C ... +60°C / -25°C ... +60°C
3
-40°C ... +70°C / -40°C ... +70°C
19
Pressure range p-Sensor
A
-
B
absolute 0 8 ... 5 2 bar
C
absolute 2 0 ... 10 0 bar
D
absolute 4 0 ... 20 0 bar
F
relative 0 ... 4 0 bar / 0 ... 58 0 PSI
G
relative 0 ... 10 0 bar / 0 ... 145 0 PSI
H
relative 0 ... 25 0 bar / 0 ... 362 6 PSI
20
Cable connection
1
2x M12 , 2x M8
3
2x M12
21
Power supply
B
External with backup battery
C
Autarkic with battery pack (5 years)
22
EX certification
1
ATEX Zone 1 / IEC-Ex Zone 1, Group IIB
2
ATEX Zone 1 / IEC-Ex Zone 1, Group IIC
3
CSA Class 1 Div 1, Group CD
23
I/O (Interface configurations)
A
Impulse LF + Status (not galvanically isolated)
B
Impulse HF (galvanically isolated)
C
Encoder
D
RS485 (externally powered)
E
Encoder + Impulse (not galvanically isolated)
F
Impulse LF + Status (galvanically isolated)
G
Impulse HF + Status (galvanically isolated)
H
Encoder + Impulse LF (galvanically isolated)
I
RS485 Modul - battery powered (external)
J
RS485 Modul - line powered (external)
K
Encoder + Impulse HF (not galvanically isolated)
L
2 x LF-Impulses (galvanically isolated)
24
Conformity
2
PED
3
MID, PED
25
Customized solution
XX
-
137

Publicidad

Tabla de contenido
loading

Tabla de contenido