CAME Z Serie Manual De Instrucciones página 10

Ocultar thumbs Ver también para Z Serie:
Tabla de contenido

Publicidad

SELEZIONI FUNZIONI - SELECTION OF FUNCTIONS - SÉLECTION FONCTIONS
1
2
3
4
Dip-switch 1/ON(2OFF)
Funzione apertura-stop-chiusura stop
(collegamento ai morsetti 2-7)
Dip-switch 2/ON(1OFF)
Funzione apertura-chiusura-inversione
(collegamento ai morsetti 2-7)
Dip-switch 3/ON(4OFF)
Funzione apertura pedonale (del motore
M2 collegato ai morsetti 2-Ap)
Dip-switch 4/ON(3OFF)
Funzione apertura parziale (del motore
M2 collegato ai morsetti 2-Ap)
Dip-switch 5/ON(6OFF)
Funzione stop parziale (dei motori
collegati ai morsetti 2-C3)
Dip-switch 6/ON(5OFF)
Funzione attesa ostacolo (dei motori
collegati ai morsetti 2-C3):
Al rilevamento di ostacolo, il motore si
arresta e riprende, nella stessa direzione,
ad ostacolo rimosso.
Dip-switch 7/ON(8OFF)
Funzione lampeggiatore ciclo (collegato
ai morsetti 10-Ex)
Dip-switch 8/ON(7OFF)
Funzione lampada di cortesia (collegato
ai morsetti 10-Ex)
Dip-switch 9/ON
Funzione incremento (20%) parametri
assorbimento (vedere dip-switch 10)
Dip-switch 10/ON
Esecuzione autotest
-10-
FUNKTIONSWAHL- SELECCIÓN DE LAS FUNCIONES
5
6
7
8
9
10
ITALIANO
ITALIANO
ITALIANO
ITALIANO
ITALIANO
ENGLISH
ENGLISH
ENGLISH
ENGLISH
ENGLISH
Dip switch 1/ON(2OFF)
Open-stop-close-stop function
(actuated by switch connected across
terminals 2-7)
Dip switch 2/ON(1OFF)
Open-close-reverse function
(actuated by switch connected across
terminals 2-7)
Dip switch 3/ON(4OFF)
Opening of gate to allow pedestrian
travel (actuation of motor 2, connected
across terminals 2-Ap)
Dip switch 4/ON(3OFF)
Partial opening function (actuation of
motor 2, connected across terminals 2-Ap)
Dip switch 5/ON(6OFF)
Partial stop function (on motors
connected across terminals 2-C3)
Dip switch 6/ON(5OFF)
Wait-for-obstacle function (on motors
connected across terminals 2-C3)
The motor shuts down when an obstacle is
detected, and resumes operation in the
same direction when the obstacle is
removed.
Dip switch 7/ON(8OFF)
Flashing light during operating cycle
(light connected across terminals 10-Ex)
Dip switch 8/ON(7OFF)
Courtesy light function (light connected
across terminals 10-Ex)
Dip switch 9/ON
20% increase in current draw
parameters (see Dip switch 10)
Dip switch 10/ON
Execution of self-test

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Zl14

Tabla de contenido