9. Fault finding
The motor will not start
The motor cuts out
No electric current
Circuit breaker trips out
10. Specifications
Model
Motor type
Output 50 Hz (watts)
Current
Socket type
Circuit breaker
Oil failure cut-out
Weight in kg (without fuel)
Dimensions l x w x h in cm
Recommended oil
Oil sump capacity in L
Recommended fuel
Fuel tank capacity in L
Spark plug
●: standard
○: optional
Probable causes
The generating set is being charged during start-up
Fuel level too low
The fuel tap is closed
Fuel supply blocked or leaking
Clogged air filter
Control in "O" position
Defective spark plug
Probable causes
Blocked ventilation inlets
Possible overload
Probable causes
Circuit breaker tripped out
Faulty circuit breaker
Faulty plug sockets
Faulty equipment leads
Faulty alternator
Probable causes
Faulty equipment or lead
X: not possible
Remedial action
Take it off charge
Fill up with fuel
Open the fuel tap
Have the system repaired
Clean the air filter
Move the control to "I"
Replace the spark plug
Remedial action
Clean the air inlet and outlet guards
Check the load
Remedial action
Reset the circuit breaker
Have it checked, repaired or replaced
Have it checked, repaired or replaced
Change the leads
Have it checked, repaired or replaced
Remedial action
Have it checked, repaired or replaced
Djingo 2000
Vanguard 85432
1600
230 V – 6.9 A
2 x 10 / 16 A
●
●
32
52 x 37 x 41
SAE 15W40
0.6
Unleaded petrol
4
NGK BCPR5ES