7.6. Starter battery maintenance

Danger
As the battery is maintenance-free, just check the condition and tightness of the connections and its general cleanliness.

7.7. Cleaning the generating set

Washing with water using a hosepipe is not recommended.
Washing with a high-pressure hose is not permitted.
Attention
Remove all dust and debris from around the exhaust silencer (fig. A - mark 15).
Clean the generating set and in particular the air inlets and outlets of the engine and alternator using a cloth and a brush.
Check the general condition of the generating set and, if necessary, replace any faulty parts.

8. Storing the generating set

In the event that the generating set is not to be used for a long period, it must be stored in accordance with the guidelines below.
Close the fuel tap (diag. A – no. 5 & diag. C - no. 1).
Drain the fuel using an appropriate container.
1) Disconnect the fuel duct downstream of the fuel filter (diag. A – no. 12 & diag. C - no. 2).
2) Open on fuel tap.
3) Once the oil has been drained, reconnect the fuel duct filter.
Start the electrical generating set and leave it running until it runs out of fuel.
While the engine is still warm, change the engine oil (see the Changing the engine oil section).
Clean the outside of the generating set, apply a rust protection product to the damaged sections and cover it with a protective
cover to protect it from dust.
Store the generating set in a clean, dry place.
Never place the battery close to a flame or fire
Use only insulated tools
Never use sulphuric acid or acid water to top up the electrolyte level.