Compressed Air; Power Supply - Festool EAA Manual De Instrucciones Original

Ocultar thumbs Ver también para EAA:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 40
EAA
GB
SRM mobile extractor and other brands
of extractor
Connecting the control cable is no longer
possible. If the dust extractor has an appli-
ance socket with automatic switch-on unit,
the mains cable on the EAA must be plugged
into this appliance socket so that the auto-
matic switch-on unit on the dust extractor
functions. However, note the maximum ca-
pacity of the appliance socket. Not all EAA
functions can be used. We therefore recom-
mend using a Festool mobile dust extractor.
Plug the extractor hose into the extractor
opening on the dust extractor.
We recommend using rotating adapter
D50 DAS-AS to connect the extractor
hose to the dust extractor.
If the EAA is quite far away from the mo-
bile dust extractor, part of the extractor
hose should be replaced by a plastic pipe
or a steel pipe designed for extraction
systems (diameter 50 mm). This reduces
the air flow resistance in the extraction
line and improves the suction power at
the EAA.
9.2
Stationary extraction system
TURBO
Plug the control cableinto the socket on
the extraction system.
Plug the extractor hose into the extractor
opening on the extraction system (D75).
10

Power supply

Power and compressed air is supplied
through the energy box.
10.1
Power
All EAA versions have three sockets. Socket
[1-3] is connected permanently to the pow-
er. The two sockets AUTO 1 [1-9] and AUTO
2 [1-5] are live when the selector switch [1-
4] is set to the "AUTO" position. If the
switch is set to "0" or "MAN", the sockets are
disconnected from the power supply.
22
CAUTION
Risk of accident, electric shock
If tools are operated from all three sockets
simultaneously,
available at each socket is 1200W.
If the mains cable on the EAA is plugged
into the appliance socket on a dust extrac-
tor (see chapter 9.1), always observe the
maximum capacity of the appliance socket
on the dust extractor. The total power sup-
plied via the output cables on the three
EAA sockets must not exceed the maxi-
mum capacity of the appliance socket on
the dust extractor.
10.2

Compressed air

The EW versions have a non-adjustable
connection for unlubricated compressed air
[1-11].
CAUTION
Risk of accident, electric shock
The compressed air from this connection
cannot be adjusted, the pressure from the
in-house compressed-air system is sup-
plied to this connection. Festool com-
pressed
air
sanders
attached via this connection.
EW/DW versions have a maintenance unit
(see Fig.[2]), consisting of a pressure regu-
lator[2-1], manual condensate trap [2-8]
and lubricator [2-6], two adjustable connec-
tions for lubricated compressed air [1-6]
and a non-adjustable connection for unlubri-
cated compressed air [2-7]. The flow pres-
sure preset at the pressure regulator is sup-
plied to all three connections. The two con-
nections for lubricated compressed air are
for attaching pneumatic tools.
The following is required for correct opera-
tion:
– Compressed air: 6 bar flow pressure
– Min. suction capacity: 400 l/min for each