Troubleshooting and repair

Malfunctions cannot always be traced back to defects in the vacuum cleaner.
Fault
Suction power drops
Vacuum cleaner does not start
The vacuum cleaner does not start
when the tool is switched on in the >A<
or >RA< mode
PE emptying and disposal bag is sucked
against the filter
Vacuum cleaner with dust classes M
or H: with inserted filter bag, dust is
accumulating in the container
Fill level indicator lights up
Do not try anything else, contact customer services.
15
Genuine accessories
Only use original accessories.
Article designation
Folded filter cartridge FKP 4300
Folded filter cartridge FKP 4300 HEPA
Folded filter cartridge FKPN 3000 NANO
Filter bags 25 l:
Fleece filter bag FBV 25/35 (5 pcs.)
PE emptying and disposal bag FBPE 25/35 (5 pcs.)
PE emptying and disposal bag Asbestos FBPE 35
(5 pcs.)
28 - en
NOTE
Cause
Filter dirty
Filter bag full
Container full
Motor protection filter blocked
Nozzle, tube or hose blocked
Mains plug not in socket
No mains voltage
Mains connection cable defective
Cover not properly closed
Water sensor switched off
Vacuum cleaner in standby mode >A<
or >RA<
Electrical tool not plugged into socket
on the vacuum cleaner
Solenoid valve of pneumatic on-off
unit*contaminated
Incorrect position of rotary slide
Incorrect position of rotary slide
filter blocked
the suction hose is blocked
container is full
NOTE
Properties/material
Polyester material, dust class M approved (Ti15)
Polyester material, glass fibre and cellulose material, dust
class H approved (Ti26)
Polyester material with nanofibre layer, dust class M
approved (Ti201)
for 25-litre- and 35-litre plastic container, dust class M
approved (VIT610/TMO908)
Only for vacuum cleaners dust class M and H
Only for vacuum cleaners dust class H-Asbestos
Remedy
Clean
Change
Empty
Clean
Clean
Plug mains plug into socket
Check fuse
Replace
Close
Empty container
Set switch to >I< (see „3 Display and control
elements" auf Seite 23)
Plug mains plug into socket on the vacuum cleaner
Rinse with alcohol
Set rotary slide to position OPEN ▲(see „7.4 Insert
PE emptying and disposal bag*" auf Seite 26)
Set rotary slide to position CLOSE ▲(see „7.3
Insert fleece filter bag" auf Seite 26)
clean or change
clean
Empty
Order no.
416069
419190
425740
411231
425764
425757
* depending on model