Blowing function
See Fig. E.
Only use the blowing function for cleaning, removing dust from and drying machines and appliances.
Flow volume display
See fig. F.
If the container is full or if there is a blockage in the suction hose, the flow volume display lights up.
After work
See Fig. G.
1. Roll up mains connection cable and suction hose.
2. Store the accessories in the accessories holder.
Transport and storage
1. Before transport, close the locks on the upper part of the vacuum cleaner.
2. Pay attention to the weight of the vacuum cleaner, particularly if the dirt container is full.
3. Do not tilt the vacuum cleaner if there is liquid in the dirt container.
4. Store the vacuum cleaner dry and indoors, protected from frost.

4 Troubleshooting and repair

Fault
Suction power drops
Vacuum cleaner does not start
Vacuum cleaner does not start
when the electrical tool is
switched on
Do not try anything else, contact customer services.
Cause
Lid not properly closed
Filter dirty
Filter bag full
Container full
Motor protection filter blocked
Nozzle, tube or hose blocked
Mains plug not in socket
No mains voltage
Mains connection cable defective
Water sensor/floater has switched
off
Switch in position A
Electrical tool not plugged into
socket on the vacuum cleaner
Switch not in position A
Remedy
Close lid
Clean
Change
Empty
Clean
Clean
Plug in
Check fuse
Have it replaced
Empty container
Move switch to I
Plug mains plug into socket on the
vacuum cleaner
Move switch to A