3G4000W Wiring diagram
Figure 2: 3G4000W wiring diagram
WARNING: High voltage. Disconnect DC power and telephone lines prior to servicing.
Incorrect connections may result in PTC failure or improper operation. Inspect wiring and
ensure connections are correct before turning on.
Do not install the equipment in places where the signal strength does not meet the minimum
recommended signal strength level.
Do not run zone inputs and T1/R1 wiring along AC wires or other circuits with high frequency
signals in order to reduce the possibility of interference and false alarms.
Table 16: Wiring diagram description and additional information
Callout
Description
1
Telephone line connection.
2
Supervision relay
3
Z2
42
Additional information
Use no. 26 AWG wires for the connection to PSTN
Connect Z2 to dry contact outputs from the alarm
control panel
3G4000W 3G (HSPA) WIRELESS ALARM COMMUNICATOR INSTALLATION MANUAL 5.0