2. Select appropriate guide sleeve version. Guide
sleeves with various inside diameters for injectors
with a flat nozzle retaining nut are included in the
scope of delivery.
1
3
Fig. 56:
Mounting version
1 Injector with flat nozzle retaining nut
2 Injector with conical nozzle retaining nut
3 Guide sleeve for injector with flat nozzle retaining nut
4 Guide sleeve with O-ring
6.5 x 4 mm for injector with conical
nozzle retaining nut
5 Ecopur sealing ring
6 Injection chamber
!
The guide sleeve selected for an injector with a flat
nozzle retaining nut (see Fig. 56, Pos. 3) must not be
too small of too large (see Fig. 57). It must be easy
to push the guide sleeve onto the nozzle retaining
nut of the injector. If the guide sleeve sticks when
it is pushed on, this means that either the injector
nozzle retaining nut or the inner surface of the guide
sleeve is very dirty or damaged. In either case, do
not use the injector or guide sleeve.
A)
B)
Fig. 57:
Guide sleeve with injector
A Guide sleeve with overly small inside diameter
B Guide sleeve with correct inside diameter
C Guide sleeve with overly large inside diameter
Robert Bosch GmbH
2
4
5
6
458847-56_Pal
C)
Preparing for testing | CRI/CRIN 848H | 79
!
Do not perform the test if the O-ring is missing or
damaged. Always use genuine Bosch O-rings.
3. When using the guide sleeve for an injector
with a conical nozzle retaining nut, place O-ring
⌀6.5 x 4 (see Fig. 58, item 1) in the guide sleeve.
4. Remove the O-ring (Fig. 58, item 3) and check for
cracks or other damage. Immediately replace a dam-
aged O-ring (spare part 1 680 210 123).
5. Insert the O-ring (Fig. 58, item 3) in the groove in
front of the injection chamber.
6. Insert the Ecopur sealing ring (Fig. 58, item 2) in the
guide sleeve (Fig. 58, item 1).
7. Insert the guide sleeve (Fig. 58, item 1) in the injec-
tion chamber.
8. Secure the guide sleeve with the knurled screw
(Fig. 58, item 4).
1
2
3
4
Fig. 58:
Guide sleeve assembly
5.3.2
Clamping injector
i
The appropriate retaining plate for the injector con-
cerned can be found in the system software EPS 945
in the "Component selection" window under
"General values".
1. Check the knurled nut (Fig. 59, item 2) for correct
positioning (see sec. 4.7).
2. Select the appropriate retaining plate (Fig. 59,
item 9).
en