Downloading Further Instructions - Balluff BTL6-P510-M Serie Instrucciones Breves

Sistema magnetostrictivo de medición de posición
Ocultar thumbs Ver también para BTL6-P510-M Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 10
BTL6-P510-M _ _ _ _ -E2/E28-KA _ _ /LA _ _
Magnetostrictive Linear Position Sensor – Rod Style
The CE Mark verifies that our products meet
the requirements of the current EMC Direc-
tive.
Intended use
The BTL magnetostrictive linear position sensor, together
with a machine controller (e.g. PLC), comprises a position
measuring system. It is intended to be installed into a
machine or system and used in the industrial sector.
Flawless function in accordance with the specifications in
the technical data is ensured only when using original
Balluff accessories. Use of any other components will void
the warranty.
Opening the BTL or non-approved use are not permitted
and will result in the loss of warranty and liability claims
against the manufacturer.

Downloading further instructions

A complete user's guide can be downloaded from the
Internet at www.balluff.com or requested via e-mail from
service@balluff.de.
BTL6-...-KA
Mounting
surface
25.2
30-1
21
2)
17
Ø24
25
45°
4
O-ring
7.5
Support ring
Version
D1
...-E2-...
10.2 mm
...-E28-...
8 mm
2) Unusable area
3) Not included in scope of delivery
1
english
Nominal length =
Measuring range
3)
Magnet
G
Thread M4x4/6 deep
No thread
General safety notes
Installation and startup may only be performed by
trained specialists.
The operator is responsible for ensuring that local safety
regulations are observed. In particular, the operator must
take steps to ensure that a defect in the BTL will not result
in hazards to persons or equipment.
If defects and unresolvable faults occur in the BTL, take it
out of service and secure against unauthorized use.
Note on EMC characteristics
(only BTL6-P510-...-LA_ _)
EMC characteristics can only be ensured if the
BTL6-P510-...-LA_ _ is completely installed in a
grounded metal housing.
1) not for BTL6-...-LA
Dimensions and function
The BTL contains the waveguide which is protected by an
outer stainless steel tube (rod). A magnet is moved along
the waveguide. This magnet is connected to the system
part whose position is to be determined. The magnet
defines the position to be measured on the waveguide.
2)
Damping zone
63.5
G
BTL6-...-LA
25.7
21
3
25
4
7.5
UL approval
File no.
1)
E227256
Ø 48 f7
Ø 38.9
Ø 48 f7
Ø 38.9

Publicidad

Tabla de contenido
loading

Tabla de contenido