Technical Data - Electrolux EHG8830X Instrucciones Para El Uso E Instalacion

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Technical data

Appliance cat. II 2H3+
Type of gas
Natural gas
(methane)
G20 20 mbar
Liquefied petroleum gas
(LPG)
G30 29 mbar
G31 37 mbar
Burner
Auxiliary
Semi-rapid
Rapid
Triple crown
The use of larger pots than those indicated can cause excessive overheating of the knobs and top and, in
case of prolonged use, yellowing of the cover (if in stainless steel).
Electrolux declines any liability for damage due to such use.
Total heating capacity: see dataplate on the bottom of the hob.
Air necessary for combustion: 2 m
Power supply voltage 220-240 V 50-60 Hz.
The appliance complies with the following EC Directives:
– 90/396/EEC (Gas);
– 2006/95/EC (Low Voltage);
– 2004/108 CEE (Electromagnetic Compatibility).
Burner
Auxiliary
Semi-rapid
Rapid
Triple crown
Auxiliary
Semi-rapid
Rapid
Triple crown
Table of recommended pots
3
/h per kW of installed power - see dataplate.
Nominal heating
Injector
capacity
marking
in kW
70
1.0
96
2.0
119
3.0
146
4.0
50
1.0
71
2.0
86
3.0
98
4.0
Ø Pots in cm
max. Ø 18
max. Ø 18
max. Ø 22
max. Ø 30
Reduced heating
capacity
in kW
0.5
0.6
1.1
2.1
0.5
0.6
1.1
2.1
17

Publicidad

Tabla de contenido
loading

Tabla de contenido