Torque Preset (Max. 6 Torques) - Desoutter EAP2-65-TF Serie Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 43
Part no
6159932890
Issue no
02
Language English
Date
01/2010
166
Page
12 /

2.1 - Torque Preset (max. 6 torques)

Up to six torques can be preset, changed and/or activated in the first menu item:
Action
Press
to start the Torque Preset features.
Press
or
to toggle between "Toff" and "Ton".
Press
when "Toff" is flashing.
Press
when "Ton" is flashing to show the current
preset torque T1.
Press
or
to reach the new target torque for T1
(torque resolution = 0.1 Nm).
Press
to validate T1.
Press
or
to reach the new target torque for T2
(torque resolution = 0.1 Nm).
Press
to validate T2.
etc.
Press
to validate T6.
Press
during 3s to validate the new torque presets
(when needed).
Press
or
to change the activated preset
torque.
EAP-TFlex tools
PROGRAMMING
Display / Result
1st menu item - Torque Preset (max. 6 torques):
"Toff" is displayed (no torque is preset, by default). The
"Torque" LED lights ON.
"Toff" is flashing.
"Ton" or "Toff" is flashing.
"Toff" is displayed. Return to the "Torque Preset" menu.
"-T1-" is displayed for 2 s. Thereafter, the current preset
torque value T1 is displayed ("Tmax" by default).
The new target torque T1 is displayed.
The new preset torque T1 is validated.
"-T2-" is displayed for 2 s. Thereafter, the current preset
torque value T2 is displayed ("Tmax" by default).
The new target torque T2 is displayed.
The new preset torque T2 is validated.
"-T3-" is displayed for 2 s, etc.
The new target torque T6 is displayed.
The new preset torque T6 is validated.
"Ton" is displayed. The "Torque" LED still lights ON.
The six preset torques are validated. "--" is displayed. The
"Torque" LED lights OFF.
Ready to tighten.
The selected preset torque is activated and displayed.
Ready to tighten.

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Eap2-30-tf serie

Tabla de contenido