Part no
6159932890
Issue no
02
Language English
Date
01/2010
166
Page
14 /
2.4 - Access Code Activation
The Access Code can be activated in the fourth menu item::
Action
Press
to enter Access Code Activation mode.
Press
or
to define an Access Code between "-
--0" and "-999".
Press
to validate.
Press
during 3s to validate the chosen Access
Code.
The access code is inactivated from factory, by default. If you should change it, using the Advanced Programming
mode, do memorize or note your code.
2.5 - Unit Selection
The selected unit for the torque value display can be changed in the fifth menu item.
Action
Press
to change the unit for the torque value
display.
Press
or
to toggle the unit (several times, if
necessary).
When the desired unit is flashing, press
it.
Press
during 3 s to validate the selected unit.
EAP-TFlex tools
PROGRAMMING
Display / Result
4th menu item - Access Code Activation:
"---0" is displayed. The "Access Code" LED lights ON.
"---0" is flashing.
The displayed number increases or decreases between "---
0" and "-999" flashes.
The Access Code is set to the displayed number "-XXX",
which stops flashing. If the Access Code is set to "0", it
means that the Access Code is inactivated.
The "Access Code" LED lights OFF. Next time, the Access
Code will be required to enter any programming mode.
Ready to tighten.
Display / Result
5th menu item - Unit Selection:
"Nm", "FtLb" or "InLb" is displayed, depending on the
previous choice ("Nm" is selected by default).
The "Torque" LED lights ON.
The display ("Nm", "FtLb" or "InLb") starts flashing.
"Nm", "FtLb" or "InLb" starts flashing (depending on the
number of pressures).
to select
"Nm", "FtLb" or "InLb" is selected, depending on the
display. The selected unit stops flashing.
The selected unit is validated. "--" is displayed. The
"Torque" LED lights OFF.
The tool automatically checks the torque values. The tool
modifies those values, if they should be outside of the
boundaries.