Description
E512
Reading error of "Code - Station - Sequence - Cycle" parameter
E513
Reading error of "Maintenance" parameters
E514
Writing error of STATION parameter
E515
Writing error of ACCESS CODE parameter
E516
Writing error of CYCLE parameter
E517
Writing error of SEQUENCE parameter
E519
Writing error of the error table
E521
Writing error of the cycle manually set up
E524
Software version
E525
Writing error of CALIBRATION parameters
E526
Writing error of the torque coefficient
E527
Writing error of linearity table
E528
Writing error of motor offset coefficients
E529
Writing error of CRC on "Identification - Tool - Calibration" parameters.
E530
Writing error of CRC on "Code - Station - Sequence - Cycle" parameters
E531
Writing error of CRC on "Maintenance" parameters
E532
Writing error of the tool option
E533
Writing error of the tool type
E534
Writing error of approach torque
E536
Writing error of the error table
E666
Error in the linearity table.
E667
Error seeking zero position.
E668
Error
seeking
according to speed.
EAP-TFlex tools
ERROR TABLE
This error can only appear at the end of the first phase of the engine
tuning. It could be an engine problem, it could be a magnet problem in
the engine shaft extension, the power module or the DSP board. Contact
our customer service.
This error can only appear after the second phase of the engine tuning.
This can be a problem with the magnet in the engine shaft extension, or a
problem on the hall board. Contact our customer service.
offset
evolution
This error can only appear at the end of the third phase of the engine
tuning. This can be a problem with the magnet in the engine shaft
extension, or a problem on the hall board. Contact our customer service.