Installing an AC-Power Supply Module
Caution
Step 5
Step 6
Caution
Figure 3-1
Inserting the AC-Power Supply Module
100 -240
V
10-5 A
AC OK
50-6 0 HZ
DC OK
100 -240
V
10-5 A
50-6 0 HZ
ST DB Y
/
AC TIV E
TE MP
FA N
Step 7
Step 8
Step 9
Cisco Redundant Power System 2300 Hardware Installation Guide
3-4
Make sure that the power supply slot is not open for more than 90 seconds while
the system is operational.
Remove the power supply module from the power supply slot by pulling on the
extraction handle.
Insert the new power supply module into the power supply slot, and gently push
the module into the slot
When correctly inserted, the 750-W power supply face plate is flush with the RPS
2300 front panel. The 1150-W power supply module extends 3.6 inches (9.14 cm)
from the RPS 2300 front panel.
When inserting a power supply module into the RPS 2300, do not use unnecessary
force. Doing so can damage the connectors on the rear of the supply and on the
midplane.
C is co R
PS 24 50
DC OU TP
1
UT
2
3
4
5
6
SE LE CT
ST DB Y/
AC TI VE
100 -240
V
10-5 A
AC OK
50-6 0 HZ
DC OK
100 -240
V
10-5 A
50-6 0 HZ
Align the two captive screws with the screw holes in the RPS 2300 front panel.
Using a ratcheting torque screwdriver, torque each screw to 10 lbf-in. (160
ozf-in.).
Connect the power cord (CAB-16AWG-AC) to the module and to an AC-power
outlet.
Snap the AC power cord retainer into place to secure the power cord (see
Figure
3-2).