Faults - Wilo Star-Z NOVA C Instrucciones De Instalación Y Funcionamiento

Ocultar thumbs Ver también para Star-Z NOVA C:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 51
Cleaning
Replacing the motor head

Faults

Pump does not
start.
Pump is making
noises.
Installation and operating instructions Wilo-Star-Z NOVA
Clean the outside of the pump with a slightly
damp cloth only. Do not use detergents.
Warning: When removing the motor head
or pump, hot fluid may spurt out under high
pressure. Allow the pump to cool down before-
hand.
Close the stop valves before removing the pump
Page 26.
Replacing the motor head
6
Maintenance/faults
Order the service motor from a specialist retailer.
7
Causes
Interruption in the power
supply, short- circuit or
defective fuses.
Time switching function
has switched off auto-
matically (Star-Z NOVA C
version only).
Motor is blocked, e.g. by
deposits from the water
mains.
Motor scraping, e.g.
through deposits from
the water mains
Running dry, too little
water.
Note: If you cannot remedy the fault,
contact a specialist retailer.
Maintenance/faults
Page 26.
Remedies
Have the power supply
checked by a qualified
electrician.
Check the plug clock
timer setting.
Have the pump removed
by a qualified technician
Page 26.
Check that the impeller
can move by turning it
and rinse out the dirt that
has accumulated.
Check the check valves,
they must be fully open.
33