1

DESCRIPTION OF THE APPLIANCE

1.1

Characteristics

Brava Slim HE 25 T
are last generation condensing wall mount-
ed boilers which Sime has produced for heating and domestic
hot water production when combined with a storage tank. The
main design choices made by Sime for the Brava Slim HE 25
boilers are:
T
– the total pre-mix microflame burner combined with a steel
heat exchanger for heating
– the sealed combustion chamber which can be classified
"Type C" or "Type B" in relation to the room where the boiler
is installed, depending on the smoke outlet configuration
adopted during installation
– the command and control microprocessor electronic board
not only allows a better management of the heating system
and the system for domestic hot water production but it can
also be connected to a remote control with an Open Ther-
mo protocol or to air thermostats or to an external sensor.
If connected to an external sensor, the boiler temperature
varies on the basis of the external temperature according to
a selected optimal climatic curve providing significant ener-
gy and economic savings.
Other special features of the Brava Slim HE 25 T boilers are:
– the anti-freeze function which activates automatically if the
temperature of the water inside the boiler falls below the
threshold of the value set at parameter "PAR 10" and , if
there is an external sensor, if the external temperature falls
below the threshold of the value set at parameter "PAR 11".
– the anti-blocking function of the pump and diverter valve.
This activates automatically every 24 hours if no request for
heat has been made
– the chimney sweep function lasts 15 minutes and makes
the job of the qualified technician easier when measuring
the parameters and combustion efficiency
– screen display of the operating and self-diagnostic param-
eters with error code display when the fault occurs. This
makes repair interventions easier and allows appliance op-
eration to be restored correctly.
1.2

Check and safety devices

The Brava Slim HE 25 T boilers are equipped with the following
check and safety devices:
– thermal safety thermostat 100°C
– 3 bar relief valve
– heating water pressure transducer
– delivery sensor
– hot water tank sensor
– smoke probe.
d
IT IS FORBIDDEN
to commission the appliance with safety devices
which do not work or which have been tampered
with.
a
DANGER
Safety device may only be replaced by professional
qualified personnel using Sime original spare parts.
60
1.3

Identification

The Brava Slim HE 25 T boilers can be identified by means of:
this is located on the outside of the packa-
1
Packaging label:
ging and provides a code, the serial number of the boiler
and the bar code
this is located inside the front panel
2
Technical Data Plate:
of the boiler and provides the technical specification, ap-
pliance performance and any other information required
by law.
1
2
KEY:
Packaging label
1
Technical Data Plate
2
m
CAUTION
Tampering with, removing or failing to display the
identification plate or carrying out any other oper-
ation which does not allow safe identification of the
product or which may hinder installation and main-
tenance operations.
EN