1.11

Wiring diagram

BLACK
PI
BLACK
VD
2
3
BLACK
BROWN
BLUE
BROWN
L
N
BLUE
CN12
CN11
EAR
TRA
L
N
F
TRA
PI
V
EAR
EV
SM
To connect the "Air Thermostat" or, alternatively the "Remote Control", remove the
bridge between terminals 5-6.
m
CAUTION
Users must:
– Use an omnipolar cut-off switch, disconnect
switch in compliance with EN Standards
– Respect the connections L (Live) - N (Neutral)
– Ensure that the special power cable is only re-
placed with a cable ordered as a spare part and
connected by professionally qualified personnel
– Connect the earth wire to an effective earthing
system.The manufacturer is not responsible for
any damage caused by failure to earth the appli-
ance or failure to observe the information provided
in the wiring diagrams.
66
SB
SE
1
2
3
4 5 6
EV
CN13
CN14
F
CD. 6324920
Line
Neutral
Fuse (3.15AT)
Ignition transformer
System pump
Ventilator
Ignition / Detection electrode
Gas solenoid valve
Delivery sensor
CR
TA2
TA
TPA
CN15
CN3
CN5
CN6
SB
TS
TFU
SF
VD
TPA
TA-TA2
SE
CR
d
IT IS FORBIDDEN
To use water pipes for earthing the appliance.
BLUE
BROWN
RED
SF
RED
TS
SM
TFU
Hot water tank sensor
Safety thermostat
Thermal fuse
Smoke probe
Diverter valve
Pressure transducer
Air thermostat
External sensor
Remote control (instead of air thermo-
stat)
EN
V
4 3 2 1
Fig. 7