Electrical Connections - Sime Brava Slim HE 25 T Manual De Instalación Y Mantenimiento

Ocultar thumbs Ver también para Brava Slim HE 25 T:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Load loss accessory Ø 80 mm
Description
90° curve MF
45° curve MF
Horizontal extension
W. 1000 mm
Vertical extension W.
1000 mm
Wall terminal
Roof outlet terminal
(*)
(*) The losses of the roof outlet terminal at inlet include the
manifold code 8091400.
for the boiler to operate correctly it is necessary that a
NB:
minimum distance of 0.50 m of the duct is respected with a
90° inlet curve.
Example: calculation of the load loss of a Brava Slim HE 25 T
boiler (ducts Ø 80 mm).
Accessories Ø
Code
80 mm
Extension W. 1000
8077351
mm (horizontal)
Extension W. 1000
8077351
mm (horizontal)
90° curve
8077450
90° curve
8077450
Wall terminal
8089501
TOTAL
(installation permitted since the total of the load loss of the
accessories used is less than 15 mm H2O ).
72
Load loss (mm H2O)
Code
Brava Slim HE 25 T
Inlet
Outlet
8077450
0,20
8077451
0,15
8077351
0,15
8077351
0,15
8089501
0,10
8091204
0,80
Load loss (mm H2O)
Quan-
tity
Inlet
Outlet
7
7 x 0,15
-
7
-
7 x 0,15
2
2 x 0,20
-
2
-
2 x 0,25
2
0,10
0,25
400
250
120
2.13

Electrical connections

The boiler is equipped with a ready wired power cable which is
to be connected to a 230V~50 Hz network.
If this cable needs to be replaced, an original spare must be
0,25
requested from Sime .
Therefore only the connections of the original components as
0,15
shown in the table are needed. These are to be ordered sepa-
0,15
rately from the boiler.
0,15
DESCRIPTION
0,25
External sensor kit (ß=3435, NTC 10KOhm at 25°C)
Power cable (dedicated)
0,10
Remote control CR 63 (open therm)
Remote control CR 73 (open therm)
Remote control CR 83 (open therm)
Remote control HOME (open therm)
Remote control HOME PLUS (open therm)
m
CAUTION
The maintenance interventions described must
ONLY be carried out the professionally qualified per-
sonnel.
a
DANGER
Total
Before carrying out any interventions described:
1,05
– set the main system switch to "OFF"
– close the gas valve
1,05
– make sure that no hot parts inside the appliance
0,40
are touched.
0,50
0,35
3,35
To facilitate introduction of the connection wires of the option-
al components into the boiler:
– remove the two screws (1), pull the front panel (2) forwards
and release it from the top by lifting it
2
Fig. 16
8094101
6323875
8092219
8092226
8092241
8092280
8092281
OFF
1
EN
CODE
Fig. 17
Fig. 18