Fault / Malfunction Codes - Sime Brava Slim HE 25 T Manual De Instalación Y Mantenimiento

Ocultar thumbs Ver también para Brava Slim HE 25 T:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Type
No.
Description
PAR
10
Boiler Antifreeze Threshold
PAR
11
External Sensor Antifreeze Threshold
PAR
12
Heating Curve Incline
PAR
13
Minimum Heating Temperature Adjustment
PAR
14
Maximum Heating Temperature Adjustment
PAR
16
Heating Post-Circulation Time
PAR
17
Heating Pump Activation Delay
PAR
18
Re-ignition Delay
PAR
19
Domestic Hot Water Modulation with Flow meter
PAR
26
Zone Valve / Pump Relaunch Delay
PAR
29
Anti-legionella Function (Only hot water tank)
Digital / analogue Pressure switch
0 = water pressure switch
PAR
35
1 = water pressure transducer
2 = water pressure transducer (only pressure displayed)
PAR
40
Modulating Pump Speed
PAR
41
∆T Modulating pump delivery/Return
PAR
47
System pump forcing (only in winter mode)
PAR
48
INST Parameter set to default
In the event of a fault/malfunction the message "ALL" will ap-
pear on the display with the alarm number eg. "ALL 04" (Do-
mestic Hot Water Sensor Fault).
Before repairing the fault:
– disconnect the appliance from the mains power by setting
the main switch to "OFF"
– as a precautionary measure, close the gas isolation valve.
Repair the fault and start-up the boiler again.
78
DOMESTIC HOT WATER - HEATING
OFF
-- = Disabled
20 .. Par tS 1.4
Par tS 1.3 .. 80
-- = Disabled
1 = Enabled
-- = Disabled
-- = No modulation
AU = Automatic 30
0 = Disabled
1 = Enabled
RESET
after having repaired the fault, when the alarm number
NB:
appears on the display together with the message
(see figure) press the button
again.
3.5

Fault / malfunction codes

Type
No.
ALL
02
Low water pressure in system
ALL
04
Domestic hot water sensor fault
ALL
05
Delivery sensor fault
ALL
06
No flame detection
ALL
07
Sensor or safety thermostat intervenes
ALL
08
Fault in the flame detection circuit
ALL
09
No water circulating in the system
Fig. 32
ALL
11
Gas valve modulator disconnected
Incorrect configuration of the open /sealed cham-
ALL
12
ber
ALL
15
Fan check cable disconnected
Fault regarding maximum deviation between the 2
ALL
17
NTC heating sensors
ALL
28
Maximum number of consecutive releases
ALL
37
Fault due to low network voltage
ALL
40
Incorrect network frequency detected
ALL
41
Flame loss more than 6 consecutive times
ALL
42
Button fault
ALL
74
Fault in the 2nd element of the delivery sensor
ALL
81
Block due combustion during start-up
ALL
83
Irregular combustion (temporary error)
ALL
96
Block due to clogging in smoke outlet
Unit of
Range
meas-
Step
urement
0 .. +10
°C
-9 .. +5
°C
0 .. 80
-
°C
°C
seconds
0 .. 99
x 10
seconds
0 .. 60
x 10
0 .. 60
Min
-
0 .. 99
Min
-
50 .. 80
0 .. 2
-
%
.. 100
10 .. 40
%
-
-- ; 1
-
y
to start the appliance up
Description
EN
Default
1
3
1
-2
1
20
1
20
1
80
1
3
1
1
1
3
-
1
1
0
1
--
1
1
10
AU
1
20
-
0
-
-
d