ins t alled and should no t exceed 16
IT
mmH
O.
2
When t he lengt h of t he f lues ranges
ES
between 11 and 16 mm H
sary to adjust trimmer "MAX" on the fan
FR
board and set the "Max. air
vided in paragraph 4.3 in order to ensure a
correct operation.
BE
Type C (separate ø 80 flues)
GB
RO
RUS
WARNING:
- Installations with roof exit terminal (4a) and coaxial exhaust (13) require the use of a condensation recovery (12)
that has to be connected to the water drain siphon (waste water).
- The installation of the roof exit terminal (4a) requires the removal of the two ø 60 and ø 100 reducers.
- Before fitting the accessories, it is always advisable to lubricate the internal section of the gaskets with silicon
products and generally avoid the use of oils and greases.
KEY
1
ø 80 polypropylene curve, 90° MF (6 pcs) code 8077450
2 a ø 80 polypropylene extension, L. 1000 (6 pcs.) code 8077351
2 b ø 80 polypropylene extension, L. 500 (6 pcs.) code 8077350
3
Hinged tile, code 8091300
4
Roof exit terminal, L. 1381, code 8091204
4 a Coaxial roof exit terminal, L. 1285 code 8091205
5
ø 80 polypropylene extension, L. 250, with socket, code 6296513
6
ø 80polypropylene curve, 45° MF (6 pcs.), code 8077451
7
ø 80 exhaust terminal, code 8089501
8
Kit with internal/external ring nuts, code 8091500
9
ø 80 suction terminal (supplied with unit)
10
Suction/exhaust fitting, code 8091401
11
ø 80 rubber gasket (supplied with unit)
12
ø 80 condensation recovery, L. 135, code 8092800
13
ø 80/125 coaxial exhaust, L. 885, code 8091210
106
2.6.4
Maximum usable
length for coaxial
ø 80/125 flues
0, it is neces-
2
In installations with ø 80/125 coaxial
Δ
p" values pro-
exhaust, the maximum horizontal length
including the 90° cur ve, should not
exceed 5 m. For roof exits it should not
exceed 8 m along vertical linear sections.
When the length of the flue ranges from 2
to 5 m horizontally and from 4 to 8 m verti-
cally, it is necessary to adjust trimmer
"MAX" on the fan board and set the "Max.
air
order to ensure a correct operation.
Type C (separate ø 80 flues and
coaxial exhaust terminal)
TABLE OF LOAD LOSSES OF ACCESSORIES
90° MF polypropylene curve
45° MF polypropylene curve
Polypropylene extension, L. 1 000
Polypropylene extension L.500
Coaxial roof exit terminal, L. 1 285 + Fitting (pos. 10)
Roof exit terminal L. 1 381
Exhaust terminal
Suction terminal
Polypropylene extension, L. 250 with socket
Coaxial exhaust, L.885 + Fitting (pos. 10)
Condensation recovery, L. 1 35
Δ
p" values provided in paragraph 4.3 in
Load loss (mm H
2
Suction
Exhaust
1,00
1,30
0,60
0,70
0,60
0,60
0,30
0,30
-
4,30
-
1,20
-
1,30
0,20
-
-
0, 1 5
-
5,20
2,50
-
Fig. 4/a