Characteristics - Sime Planet Dewy 60 BFR Manual De Instrucciones

Ocultar thumbs Ver también para Planet Dewy 60 BFR:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 31
3

CHARACTERISTICS

3. 1
ELECTRONIC BOARD
IT
Built according to Low Voltage direc-
ES
tive CEE 73/23 and powered at 230
Volt, via a transformer it sends 24
FR
Volt power to the following compo-
nents: gas valve, safety thermostat,
BE
heating probe, external temperature
probe (optional), water pressure
GB
transducer, air pressure switch,
room thermostat or "Remote Control
Logic". An automatic and continual
RO
modulation system permits the boiler
t o adjus t power t o t he var ious
RUS
system or user needs. Electronic
components are guaranteed to ope-
rate in a temperature range from 0
to +60°C.
3. 1 . 1
Malfunctions
The led that signal errors and/or mal-
functions are indicated in fig. 12.
3. 1 .2 Devices
The electronic board is equipped with
the following devices:
– "HEATING POWER" TRIMMER
(10 fig. 13)
Adjusts maximum heating power. To
increase the value, rotate the trim-
mer clockwise, to reduce it, rotate
Blinking red fan fault led. 30 minutes after the fan turns off, the board attempts to
restart it. To identify where the fault occurred in sequence/cascade installations, turn
the CR/OFF/INV/RELEASE selector on each module to the (
Red led on, ignition blocked:
rotate selector CR/OFF/EST/INV/RESET
to release position (
to restore operation
Green led off if
power is cut-off
Flashing red led, safety stat tripped.
Rotate selector CR/OFF/EST/INV/RESET
to release position (
to restore operation
Blinking red air pressure switch fault led
112
the trimmer counter-clockwise.
– "IGNITION POWER" TRIMMER
(6 fig. 13)
Trimmer to vary the gas valve ignition
pressure level (STEP). According to
the type of gas the boiler is designed
for, the trimmer must be adjusted to
achieve a burner pressure of approxi-
mately 6.5 mm H
and 9.5 mm H
(G31). To increase pressure, rotate
the trimmer clockwise, to reduce it,
rotate the trimmer counter-clockwi-
se. The slow ignition pressure level
can be set during the first five
seconds after the burner is lit.
After setting the ignition pressure
level (STEP) according to the type of
gas, make sure that the heating gas
pressure is still the previously set
value.
– "ANN. RIT." CONNECTOR
(5 fig. 13)
The electronic board is program-
med, during heating, with a techni-
cal bur ner delay of about 90
seconds that is performed both at
cold start and subsequent ignitions.
This is to prevent rapid ignitions and
shutdowns that could, in particular,
occur in systems with high load los-
ses. Each time the boiler restarts,
after the slow ignition, for about 1
where the red fault led blinks.
communication fault
with "Logica Remote Control"
)
)
O for methane gas
2
O for propane gas
2
– DIP SWITCH (13 fig. 13)
– "Modureg Sel." connector (14 fig. 13)
– "Albatros" connector (15 fig. 13)
WARNING: All the above operations
must be performed by authorised
personnel, otherwise the warranty
shall be invalidated.
) position and check
Flashing red led,
Flashing red led, flame detection circuit fault
Flashing red led, heating sensor fault (SM)
(*) When all 0.5 to 2.5 bar leds are off, check the
water pressure transducer connection.
WARNING: the operation of plants with open ves-
sels is guaranteed only for static pressures above
0.7 bar.
minute it will run at minimum modu-
lation pressure before moving to
the set heating pressure.
The addition of a bridge will cancel
both the programmed technical
delay and the minimum pressure
operating period at ignition.
In this case, the time between shut-
down and t he next ignition will
depend on a 5°C differential detec-
ted by the heating probe (SM).
For correct module operations, the
dip switches must be positioned as
indicated below:
The bridge must always be connec-
ted.
The bridge must always be off. It is
only engaged in sequence/cascade
installations with several boilers.
Flashing red led, water
pressure is too low (*)
Flashing red led,
plant safety
valve tripped (*)
Fig. 12

Publicidad

Tabla de contenido
loading

Tabla de contenido