WATER CONNECTION
To make the connection, connect the mains line to
the appliance's connection pipe, fitting a shut-off
tap (A), to allow the water supply to be cut off when
necessary. Easily accessible filters must be fitted
downstream of the tap.
Caution - warning
The appliance must be supplied with drinking
water having the characteristics shown in the
table.
Description
Pressure
pH
Conductivity
Hardness
Salt and metallic ion con-
tent
Chlorides
Sulphates
Iron
Copper
Manganese
GAS CONNECTION
Important
Those authorised to carry out this opera-
tion must have experience acquired and
certified in the specific sector, must make
the connection to the proper standards,
and must comply with all the relevant regu-
To make the connection, connect the mains line to
the appliance's connection pipe, fitting a shut-off
tap (A), to allow the gas supply to be cut off when
necessary.
Important
The tap (A), not supplied with the appliance,
must be installed in an easily accessible
position and its status (on or off) must be
obvious at a glance.
Value
200÷450 kPa (2÷ 4 bar)
7÷7.5
< 200 mS/cm
9÷13°f (5÷7°d, 6.3÷8.8°e,
90÷125 ppm)
< 30 mg/l
< 40 mg/l
< 0,1 mg/l
< 0.05 mg/l
< 0,05 mg/l
- 21 -
A
lations and legislation. Once the connec-
tion has been made, before the appliance is
put into operation a general check must be
made to ensure there are no gas leaks.
A
IDM-39616001600.tif