Descargar Imprimir esta página

Deltaplus N95 Manual De Instrucciones Utilización Y Mantenimiento página 2

Publicidad

Idiomas disponibles

Idiomas disponibles

NIOSH N95-N99 APPROVED
PARTICULATE RESPIRATOR
DELTA PLUS GROUP
B.P. 140 - ZAC La Peyrolière
84405 APT Cedex – France
http://www.deltaplus.eu
This respirator helps protect against certain particles. Misuse may result in sickness or death.
For proper use, see supervisor, or instructions, or contact us.
IMPORTANT:
Before use, the wearer must read and understand these User Instructions.
Keep insert for reference.
USE FOR:
Solids such as those from processing minerals, coal, iron ore, flour, and certain other
substances. Liquid or non-oil based particles from sprays that do not also emit oil aerosols or
vapours.
DO NOT USE FOR:
Paint spray, oil aerosols, gases, vapours, asbestos or sandblasting. This respirator does not
supply oxygen.
USE INSTRUCTIONS:
1. Failure to follow all instructions and limitations on the use of this respirator and/or failure
to wear this respirator during all times of exposure can reduce respirator effectiveness and
may result in sickness or death.
2. Before occupational use of this respirator, a written respiratory protection program must
be implemented meeting all the requirements of OSHA 29 CFR
1910.134 such as training and fit testing and applicable OSHA substance specific
standards. In Canada, CSA standard Z94.4-93 requirements must be met.
3. The particles which can be dangerous to your health include those so small that you cannot
see them.
4. Leave the contaminated area immediately and contact supervisor if dizziness, irritation, or
other distress occurs.
5. Store the respirator away from contaminated areas when not in use.
6. Dispose of used product in accordance with applicable regulations.
USE LIMITATIONS:
1. This respirator does not supply oxygen. Do not use in atmospheres containing less than
19.5% oxygen.
2. Do not use when concentrations of contaminants are immediately dangerous to life and
health are unknown or when concentrations exceed 10 times the permissible exposure
limit (PEL) or according to specific OSHA standards or applicable government regulations,
whichever is lower.
3. Do not alter abuse or misuse this respirator.
4. Do not use with beards or other facial hair or other conditions that prevent a good seal
between the face and the edge of the respirator.
TIME USE LIMITATIONS:
If respirator becomes damaged, soiled, or breathing becomes difficult, leave the
contaminated area and replace the respirator.
PICTOGRAM MEANING:
See information supplied by the manufacturer
Maximum relative humidity of storage conditions
Temperature range of storage conditions
End of shelf life (year/month)
WARNING
FITTING INSTRUCTIONS:
To be followed each time respirator is worn.
1. Pre-stretch top and bottom straps before placing respirator on the face
2. Cup the respirator in your hand, with the nosepiece at your fingertips,
allowing the headbands to hang freely below your hand.
3. Position the respirator under your chin with the nosepiece up. Pull the top
strap over your head resting it high at the top back of your head. Pull the
bottom strap over your head and position it around the neck below the ears.
4. Place your fingertips from both hands at the top of the metal nosepiece.
Using two hands mold the nose area to the shape of your nose by pushing
inward while moving your fingertips down both sides of the nosepiece.
Pinching the nosepiece using one hand may result in improper fit and less
effective respirator performance. Use two hands.
5. Perform a User Seal Check prior to each wearing. To check fit, place both
hands completely over the respirator and exhale. Be careful not to disturb the
position of the respirator. If air leaks around nose, readjust the nosepiece as
described in previous step. If air leaks at the respirator edges, work the straps
back along the sides of your head. If you CANNOT achieve a proper fit, DO NOT
enter the contaminated area. See your supervisor.
REMOVAL INSTRUCTIONS:
See step 3 of Fitting Instructions and cup respirator in hand to maintain position on f ace.
Pull bottom strap overhead. Still holding respirator in position, pull top strap overhead and
remove respirator.
This respirator contains no components made from natural rubber latex.
NIOSH APPROVED: N95 or N99
These respirators are approved only in the following configurations:
NIOSH Technical
Protection
Cetificate
TC-84A-4331
N95
TC-84A-4399
N99
TC-84A-4329
N95
TC-84A-8545
N95
TC-84A-4471
N95
TC-84A-4468
N95
TC-84A-4399
N99
PROTECTION:
N95 or N99-Particulate Filter (95%(N95) or 99%(N99) filter
efficiency level) effective against particulate aerosols free of oil ;
Time use restrictions may apply
CAUTIONS AND LIMITATION:
A. Not for use in atmospheres containing less than 19.5 percent oxygen.
B. Not for use in atmospheres immediately dangerous to life or death.
C. Do not exceed maximum use concentrations established by regulatory standards.
J. Failures to property uses and maintain this product could result in injury or death.
M. All approved respirators shall be selected firmed used and maintained in accordance with
MSHA, OSHA and other applicable regulations.
N. Never substitute, modify, add or omit parts. Use only exact replacement parts in the
configuration as specified by the manufacturers.
O. Refer to user's instructions and or maintenance manuals for information on use and
maintenance of these respirators.
P. NIOSH does not evaluate respirators as surgical masks.
S. Special or critical User's Instructions and/or specific use limitations apply. Refer to User's
Instructions before donning.
NIOSH APPROVED: N95 or N99
95%(N95) or 99%(N99) efficient against particulate aerosols free of oil. This respirator
helps protect against certain particulate contaminants but does not eliminate exposure to
or the risk of contracting disease or infection. Misuse may result in sickness or death.
S* - Special or Critical User's Instructions:
above have been manufactured by Shanghai Dasheng Health Products Manufacture Co.,Ltd
for Delta Plus Group under certificate numbers listed above TC-xxx-xxxx.
IMPORTANT NOTICE:
N95 or N99 masks are only sold by DELTA PLUS. If purchased from other company, agent or
distributor please mind to get our written confirmation.
For more information call:
Tel: +33 490 742 033 / Fax: +33 490 74 32 59
or visit our Website:
Update 27-08-2020
Minimum
Respirator
efficiency test
agent
M1200C
95% Nacl
M1300VC
99% Nacl
M1195B
95% Nacl
M1200VC
95% Nacl
M1200VPC
95% Nacl
M1200VPWC
95% Nacl
M1200VCPL
99% Nacl
WARNING
the filtering face piece respirator listed
http://www.deltaplus.eu
Cautions and
limitations
ABCJMNOP
ABCJMNOPS*
ABCJMNOP
ABCJMNOPS*
ABCJMNOP
ABCJMNOP
ABCJMNOPS*

Publicidad

loading

Este manual también es adecuado para:

N99