EN
Remove the urinal flush control.
1
Open the protection flap and remove
the urinal flush control.
2
Disconnect the rechargeable battery
compartment cable.
3
Test and charge the rechargeable
battery with charger (art. no.
116.452.00.1), see user manual
965.861.00.0.
Install the urinal flush control.
4
Plug in the rechargeable battery
compartment cable.
5
Insert the urinal flush control and
close the protection flap.
Result
The urinal is once more ready for
operation.
Optimise the detection
distance
If flushes are actuated too soon, too late or
unintentionally, you can optimise the
detection distance of the IR sensor. For this,
you must remeasure the detection range.
Deactivate the urinal flush control.
1
Open the protection flap and remove
the urinal flush control.
20
2
Disconnect the cable for the battery
or rechargeable battery
compartment.
Restart the urinal flush control.
3
Plug in the cable for the battery or
rechargeable battery compartment.
4
Insert the urinal flush control and
close the protection flap.
Optimise the detection distance.
You must optimise the detection
distance within the first 30 minutes
after activating the power supply.
5
Hold a white sheet of paper in front of
the IR sensor on the bottom edge of
the urinal ceramic. 2 short signal
tones will sound after 2 seconds,
then keep the white sheet in front of
the IR sensor for a further
15 seconds.
6
Remove the white sheet as soon as a
signal tone sounds every second.
7
Step away from the urinal for at least
10 seconds so that the detection
range can be remeasured.
8
Once this process been completed,
a flush is actuated.
B1243-001 © 10-2017
966.934.00.0 (01)