Technical data
FUNCTION
Selection of trigger mode, 2-times / 4-times
Control of current/voltage/ wire feed speed
Wire inching
Torch cooling
Hot-start %
Hot-start-time, sec.
Arc power, %
Gas pre-flow, sec.
Soft-start, m/min
Hot-start, %
Hot-start-time, sec.
Slope down time, sec.
Stop amp, A
Stop Amp time, sec.
Gas post-flow, sec
Sequence timer / Spot welding time, sec.
DUO Plus™ efficiency, %
DUO Plus™ time, sec.
Electronic choke
Sequence, Sequencesteps
EC DECLARATION OF CONFORMITY
MIGATRONIC A/S
Aggersundvej 33
9690 Fjerritslev
Denmark
hereby declare that our machine as stated below
Type: SIGMA Select
conforms to directives: 2014/35/EU
2014/30/EU
2011/65/EU
European standards:
EN/IEC60974-1
EN/IEC60974-2
EN/IEC60974-5
EN/IEC60974-10 (Class A)
Issued in Fjerritslev 27.11.2017
Niels Jørn Jakobsen
CEO
30
PROCESS
VALUE RANGE
MIG/MAG
2/4
-
local/torch control/remote control
MIG/MAG
-
water cooled/air cooled
MMA
0.0-100.0
MMA
0.0-20.0
MMA
0.0-150.0
MIG/MAG
0.0-10.0
MIG/MAG
0.5-24.0
Synergic
-99-(+)99
Synergic
0.0-20.0
Synergic
0.0-10.0
Synergic
0-100
Synergic
0.0-10.0
MIG
0.0-20.0
MIG
0.0-50.0
MIG
0-50
MIG
0.1-9.9
MIG
-5.0-(+)5.0
MIG
9