Troubleshooting; Troubleshooting Table - SICK GRSE18V Instrucciones De Operación

Ocultar thumbs Ver también para GRSE18V:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 67
7

Troubleshooting

7.1

Troubleshooting table

8021182.16B5 | SICK
Subject to change without notice
Figure 11: sensing range areas
Table 6: Definition of sensing range
1
Sensing range
1
3
Sensitivity setting
Sensor which it is not possible to set: The sensor is adjusted and ready for operation.
The sensitivity is adjusted with the potentiometer (type: 270°). Clockwise rotation: operat‐
ing reserve increased; counterclockwise rotation: operating reserve reduced. We recom‐
mend setting the potentiometer to "Maximum".
The sensor is adjusted and ready for operation.
4
Test input
Test input: The GRSE18(S)V sensors feature a test input ("TI" or "Test" on the connection
diagram
[table
2]), which can be used to switch the sender off and, therefore, check that
the sensor is functioning correctly: If female cable connectors with LED indicators are
used, you must ensure that the TI is assigned accordingly.
There must be no object between the sender and receiver; activate the test input (see the
connection diagram
[table
object is simulated. Use the following table to check the function. If the switching output
fails to behave in accordance with the following table, check the application conditions.
See section Fault diagnosis.
The Troubleshooting table indicates measures to be taken if the sensor stops working.
Table 7: Troubleshooting
LED indicator/fault pattern
Green LED does not light up
Green LED does not light up
Green LED does not light up
GRSE18(S)V
0 ... 15 m
2], TI at 0 V). The send LED is shut down or the detection of an
Cause
No voltage or voltage below
the limit values
Voltage interruptions
Sensor is faulty
TROUBLESHOOTING
Measures
Check the power supply,
check all electrical connec‐
tions (cables and plug connec‐
tions)
Ensure there is a stable power
supply without interruptions
If the power supply is OK,
replace the sensor
7
11

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para: