10
Technical specifications
Sensing range
Sensing range max.
Light spot diameter/distance
Supply voltage V
S
Output current I
max.
Max. switching frequency
Max. response time
Enclosure rating
Protection class
Circuit protection
Ambient operating temperature
1
Object with 90 % remission (based on standard white DIN 5033)
2
Limit value; operation in short-circuit protection mains max. 8 A; residual ripple max. 5 V
Usage category: AC-15, DC-13 (EN 60947-1)
4
5
With light / dark ratio 1:1
6
Signal transit time with resistive load
7
valid for Q\ on Pin2, if configured with software
Reference voltage DC 50 V
8
10
A = U
-connections reverse polarity protected
V
B = inputs and output reverse-polarity protected
D = outputs overcurrent and short-circuit protected
11
IP68: according to EN 60529 (water depth of 10 m / 24 h).
IP69K: according to ISO 20653:2013-03.
8021182.16B5 | SICK
Subject to change without notice
GRSE18(S)-xxx2xV, Infraredlight
0 ... 10 m
0 ... 15 m
420 mm / 10 m
DC 10 ... 30 V
2
100 mA
1,000 / s
5
< 0,5 ms
6
IP67, IP68, IP69K
11
III
8
A, B, D
10
-25 °C ... +55 °C
TECHNICAL SPECIFICATIONS
GRSE18(S)-xxx4xV, visible red light
0 ... 10 m
0 ... 15 m
250 mm / 10 m
DC 10 ... 30 V
2
100 mA
1,000 / s
5
< 0,5 ms
6
IP67, IP68, IP69K
11
III
8
A, B, D
10
-25 °C ... +55 °C
ss
10
13