Descargar Imprimir esta página

Disassembly And Disposal; Maintenance - SICK CM30-30BPC-KC1S01 Instrucciones De Operación

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 43
7

DISASSEMBLY AND DISPOSAL

7
Disassembly and disposal
8

Maintenance

8
Push-button
LED – green
LED – yellow
Time (sec)
0
1
2
B - Setting - Object, object available
Pushbutton > press for 6 seconds until the LEDs flash twice per second. The object is
calibrated after the pushbutton has been released for 3 seconds.
Push-button
LED – green
LED – yellow
Time (sec)
0
1
2
C - Setting - Normally open / normally closed
Pushbutton > press for 9 seconds until the LEDs flash three times per second. Nor‐
mally open / normally closed status switches after the pushbutton has been released
for 3 seconds.
Push-button
LED – green
LED – yellow
Time (sec)
0
1
2
D - Setting - Return to factory setting
Pushbutton > press for 12 seconds to return the sensor to its factory setting.
The sensor must be disposed of according to the applicable country-specific regula‐
tions. Efforts should be made during the disposal process to recycle the constituent
materials (particularly precious metals).
SICK sensors are maintenance-free.
We do, however, recommend that the following activities are undertaken regularly:
Clean the active detection surface
Check the screw connections and plug connectors
No modifications may be made to devices.
Subject to change without notice. Specified product properties and technical data are
not written guarantees.
3
4
5
6
7
3
4
5
6
7
3
4
5
6
7
8
9
10
11
12
8
9
10
11
12
8
9
10
11
12
8021279 | SICK
Subject to change without notice
13
13
13

Publicidad

loading