Operating instructions
LGT
ATTENTION
Strip pair 1
blanked
8 007 557/S711/2008-06-04 © SICK AG • Safety Systems • Germany • All rights reserved
Blanking
6. Switch the power supply off and then on again (or
disconnect and reconnect the reset jumper).
7. Recalibrate the sender power as described in point 6.
When blanking has been completed, the protective field must
be checked with a test rod (diameter 30 mm).
The blanking setting remains stored even if the supply voltage
fails.
An existing blanking setting is displayed continuously as per
Fig., bottom.
Gaps in the protective field
Since gaps in the protective field are produced as a result of
blanking, these gaps must be guarded by other (e.g.
mechanical) safety devices.
Strip pair 2
blanked
GB
Chapter 7
Both strip pairs
blanked
195