10
Disassembly and disposal
11
Maintenance
12
Technical data
Sensing range (with reflector P250F)
Light spot diameter/distance
Supply voltage U
B
Ripple
8020349.14CS | SICK
Subject to change without notice
en
LED indicator/fault pattern
Green LED flashes
Switching outputs do not
behave in accordance with
table
4,
table 5
Yellow LED flashes
The sensor must be disposed of according to the applicable country-specific regula‐
tions. Efforts should be made during the disposal process to recycle the constituent
materials (particularly precious metals).
NOTE
Disposal of batteries, electric and electronic devices
•
According to international directives, batteries, accumulators and electrical or
electronic devices must not be disposed of in general waste.
•
The owner is obliged by law to return this devices at the end of their life to the
respective public collection points.
•
This symbol on the product, its package or in this document, indicates
that a product is subject to these regulations.
SICK sensors are maintenance-free.
We recommend doing the following regularly:
•
Clean the external lens surfaces
•
Check the screw connections and plug-in connections
No modifications may be made to devices.
Subject to change without notice. Specified product properties and technical data are
not written guarantees.
Cause
IO-Link communication
1. IO-Link communication
2. Change of the configuration
3. Short-circuit
Distance between sensor and
reflector is too large / light
beam is not completely
aligned to the reflector /
reflector is not suitable / Front
screen and/or reflector is con‐
taminated.
WLG16P
0 m ... 5 m
1)
Ø 80 mm (5 m)
DC 10 ... 30 V
≤ 5 V
SS
TROUBLESHOOTING
Measures
None
1. None
2. Adjustment of the configura‐
tion
3. Check electrical connections
Check sensing range / check
alignment / SICK reflector is
recommended / Cleaning of
the optical surfaces (sensor
and reflector).
9
13