Technical Specifications - SICK HSE18 Instrucciones De Operación

Ocultar thumbs Ver también para HSE18:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 114
11

TECHNICAL SPECIFICATIONS

11
Technical specifications
Laser class
Sensing range
Sensing range max.
Light spot diameter/distance
Supply voltage U
B
Output current I
max.
Switching current (switching voltage)
I
max.
Communication mode
IO-Link
Switching frequency
Max. response time
Enclosure rating
Protection class
Circuit protection
Ambient operating temperature
1)
Limit values. U
connections reverse-polarity protected. Residual ripple max 5 V
B
2)
Object with 90 % remission (based on standard white DIN 5033)
2)
Limit values
3)
Usage category: AC-15, DC-13 (EN 60947-1)
4)
With light / dark ratio 1:1, deviating values possible with IO Link
5)
Signal transit time with resistive load
6)
Replaces IP69 K pursuant to ISO 20653: 2013-03
7)
Rated voltage AC/DC 250 V, overvoltage category II
8)
valid for Q\ on Pin2, if configured with software
8)
A = U
-connections reverse polarity protected
B
B = inputs and output reverse-polarity protected
D = outputs overcurrent and short-circuit protected
Reference voltage DC 50 V
9)
24
HSE18-xxx2xx
-xxx1xx
0 ... 20 m
0 ... 15 m
0 ... 25 m
0 ... 20 m
400 x 200
1,400 mm / 10
mm / 10 m
m
DC 10 ... 30 V
DC 10 ... 30 V
1)
≤ 100 mA
≤ 100 mA
COM2
COM2
1.1
1.1
1,000 Hz
1,000 Hz
4)
4)
≤ 0.5 ms
≤ 0.5 ms
5)
5)
IP67, IP69
6)
IP67, IP69
III
III
A, B, D
8)
A, B, D
8)
-40 ... +70 °C
-40 ... +70 °C
-Mxx2xx / -
-Mxx1xx / -
Lxx2xx / -
Lxx1xx / -
Uxx2xx
Uxx1xx
0 ... 20 m
0 ... 15 m
0 ... 25 m
0 ... 20 m
400 x 200
2 mm / 5 m
mm /10 m
AC 90 ... 250
AC 90 ... 250
1)
V
V
2)
2)
≤ 10 mA
≤ 10 mA
3)
COM2
COM2
1.1
1.1
1,000 Hz
1,000 Hz
4)
≤ 0.5 ms
≤ 0.5 ms
5)
6)
IP67, IP69
6)
IP67, IP69
II
7)
II
7)
A, B, D
8)
A, B, D
-40 ... +70 °C
-40 ... +70 °C
PP
HSE18L
1
0 ... 50 m
0 ... 60 m
2 mm / 5 m
DC 10 ... 30 V
1)
≤ 100 mA
3)
1,000 Hz
4)
4)
≤ 0.5 ms
5)
5)
6)
IP67, IP69
6)
III
8)
A, B, D
8)
-30 ... +55 °C
8017854.1A15 / 2020-12-14 | SICK
Subject to change without notice

Publicidad

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

Hse18l

Tabla de contenido