RIB T2 Manual Del Usuario página 21

Cuadro electronico de mando para uno o dos motores monofasicos
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

POINT B
- SETTINGS
DIP 1 (ON) MOTOR ROTATION DIRECTION CHECK
(See Point C)
DIP 2 (ON) PROGRAMMING (See Point D)
DIP 1-2 STORING/ERASING RADIO CODES FOR
MOTOR CONTROL (only CRX control board) (See Point G,
H and I)
DIP 2-1 PROGRAMMING OF THE PEDESTRIAN OPENING (See
Point F)
DIP 3
ON - Automatic Closing ENABLED
OFF - Automatic Closing DISABLED
DIP 4
ON - Photocells active only in closing
OFF - Photocells always active
DIP 5
ON - blinker pre-flashing
OFF - blinker normal-flashing
DIP 6
ON - STEP BY STEP
Single pulse contact (K BUTT)
Pedestrian button (PED BUTT)
Radio Receiver command
OFF - AUTOMATIC
Single pulse contact (K BUTT)
Pedestrian button (PED BUTT)
Radio Receiver command
DIP 7
ON - low speed in approaching ENABLED
OFF - low speed in approaching DISABLED
DIP 8
ON - electric lock command ENABLED
OFF - electric lock command DISABLED
DIP 9
ON - Hammering on complete close position to ease Manual
Release
- Hammering before opening to ease electric lock
unlocking
OFF - no impulse
DIP 10 ON - Extra thrust when reached closing position to make sure
that the mechanical bolt is fixed into the ground
OFF no impulse
DIP 11 ON - black out function ENABLED (See chart 2)
OFF - black out function DISABLED
DIP 12 Available for future applications
DIP 13 ON - safety strip self-test ENABLED
OFF - safety strip self-test DISABLED
DIP 14 to select type of motor (see chart 1)
DIP 15 to select type of motor (see chart 1)
DIP 16 to select type of motor (see chart 1)
JP 17 OPEN JUMPER 1 motor (M1) - 1 leaf
CLOSE JUMPER 2 motors (M1 and M2) - 2 leaves
JP1 => Pay attention that the jumper is inserted!
JP2 => Pay attention that the jumper is inserted!
JP3 => Pay attention that the jumper is inserted!
TORQUE TR1 Electronic regulator for motor torque
Adjustment of motor torque is carried out using the TORQUE Trimmer
which varies the output voltage to the head/s of the motor/s (turn
clockwise to increase torque).
This torque control is activated after 2 seconds form any manoeuvre
begging, whereas the motor is turned on at full power to guarantee the
starting at the manoeuvre begging.
PAY ATTENTION: IF
THE
TORQUE
CHANGED, IT IS PREFERABLE TO REPEAT THE
TIME PROGRAMMING.
LOW SPEED TR2 Electronic regulator for low speed on approach
WARNING: THE LOW SPEED FEATURES IS NOT AVAILABLE FOR
THE HYDRAULIC MOTORS (SEE CHART 1 POINTS 4-
5-8).
Adjustment of low speed is carried out using the LOW SPEED Trimmer
which varies the output voltage to the head/s of the motor/s (turn
clockwise to increase speed). Adjustment is carried out to establish the
correct speed at the completion of opening and closing, depending on
TRIMMER
SETTING
IS
TABLE 1
TYPE OF MOTOR
1
KING 230/50
KING L 230/50
KING 220/60
KING L 220/60
KING ICE 230/50
2
MAGIC IRR. 105°
MAGIC IRR. 180°
MAGIC REV. 105°
MAGIC REV. 180°
PRATIC
3
PRINCE REV
4
IDRO 27/1B
IDRO 27/R
IDRO 27 SUPER/R
IDRO 27 SUPER/1B
5
FLUID R DVI
FLUID R SVI
FLUID 2B DVI
FLUID 2B SVI
IDRO 39/R
IDRO 39/1B
IDRO 39/2B
6
KING FAST 230/50
KING 120/60
KING L 120/60
7
PRINCE WITH BRAKE
8
IDRO C 27/1B
IDRO C 27/2B
IDRO C 27/R
the structure of the gate, or if there is any light friction that could
compromise the correct working of the system. The low speed is
activated (DIP7 OFF) when the gate leaf is 0.50-0.60 meters away from
the complete close or open position.
LED WARNING
DL1 - programming activated (red)
DL2 - radio code programming (green) (only for CRX)
DL3 - gate opening M2 (green)
DL4 - gate closing M2 (red)
DL5 - gate opening M1 (green)
DL6 - gate closing M1 (red)
DL7 - photocell contact (NC) (red)
DL8 - safety strip contact (NC) (red)
FUSES
F1 T100mA
Accessories protection fuse
F2 5A
Motor protection fuse
POINT C
- MOTOR ROTATION DIRECTION CHECK
1 - Unlock the operators with the Manual Release, swing open the
leaves about halfway, lock the operators.
2 - Turn DIP1 to ON position, LED DL1 starts blinking.
3 - Press the PROG button and hold it (movement is now performed
in "man present" mode, open-stop-close-open-etc.).
When RED LEDS DL4 and DL6 are on, the gate leaves are closing
(with a phase shift of 4 seconds).
When GREEN LEDS DL3 and DL5 are on, the gate leaves are
opening (with a phase shift of 2 seconds).
Should any of the leaf open instead of closing, release PROG
button, turn off the main power and reverse the two phase wires
(V1/2 and W1/2) of the relevant motor.
4 - Press the PROG button and hold it to CLOSE completely the
gate, check leaves swinging and the closing mechanical stopper
position.
5 - Press the PROG button and hold it to OPEN completely the gate,
CODE
DIP 14
DIP 15
AA14001
OFF
OFF
AA14010
AA14002
AA14011
AA14019
AA10960
ON
OFF
AA10965
AA10920
AA10930
AA18001
AA14045
OFF
ON
AA10863
ON
ON
AA10860
AA10867
AA10879
AA10899
OFF
OFF
AA10901
AA10897
AA10898
AA10871
AA10876
AA10881
AA14008
ON
OFF
AA14003
AA14012
AA14040
OFF
ON
AA10884
ON
ON
AA10882
AA10883
G G
B B
DIP 16
OFF
OFF
OFF
OFF
ON
ON
ON
ON

Publicidad

Tabla de contenido
loading