Nice For-Max T Guía Rápida Para La Instalación Y El Uso página 42

Tabla de contenido

Publicidad

EN
"SUN" SENSOR – This sensor protects what is underneath the awning when sunlight is especially strong. The
manual commands sent by the user prevail over the autonomous operation of the system and the interaction between the
two modes is as follows:
– autonomous operation – When the sensor detects a luminous intensity above the set threshold, after 2 minutes the For-
Max T commands the opening of the awning (▼). When the luminous intensity drops below the set threshold, after 15 min-
utes the For-Max T commands the awning to rise (▲).
– manual operation – Manual commands can be sent at any time. These commands co-exist and overlap the commands
sent automatically by the system.
7
Klux
45
40
35
30
sun
25
brightness
20
15
10
5
0
autonomous
operation
manual
operation
sun brightness
"1"
after 2 minutes
system deactivated
momentary drop in brightness, of small
entities, within the hysteresis threshold
system active
manual commands enabled
positioned at 50%
of the set threshold
set threshold
hysteresis threshold
"0"
system deactivated
after 10 minutes
42

Publicidad

Tabla de contenido
loading

Tabla de contenido